      Scatter and crosstalk corrections for 99m Tc/123 I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators : Scatter and crosstalk corrections for dual-radionuclide imaging

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for (99m)Tc/(123)I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c).

          Related collections

          Most cited references25

          • Record: found
          • Abstract: not found
          • Article: not found

          Zum Mechanismus des lichtelektrischen Prim�rstromes in isolierenden Kristallen

          Karl Hecht (1932)
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A Monte Carlo program for the simulation of scintillation camera characteristics.

            There is a need for mathematical modelling for the evaluation of important parameters for photon imaging systems. A Monte Carlo program which simulates medical imaging nuclear detectors has been developed. Different materials can be chosen for the detector, a cover and a phantom. Cylindrical, spherical, rectangular and more complex phantom and source shapes can be simulated. Photoelectric, incoherent, coherent interactions and pair production are simulated. Different detector parameters, e.g. the energy pulse-height distribution and pulse pile-up due to finite decay time of the scintillation light emission, can be calculated. An energy resolution of the system is simulated by convolving the energy imparted with an energy-dependent Gaussian function. An image matrix of the centroid of the events in the detector can be simulated. Simulation of different collimators permits studies of spatial resolution and sensitivity. Comparisons of our results with experimental data and other published results have shown good agreement. The usefulness of the Monte Carlo code for the accurately simulation of important parameters in scintillation camera systems, stationary as well as SPECT (single-photon emission computed tomography) systems, has been demonstrated.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Recent progress in CdTe and CdZnTe detectors

                Bookmark

                Author and article information

                Journal
                Medical Physics
                Med. Phys.
                Wiley
                00942405
                December 2015
                November 11 2015
                November 11 2015
                : 42
                : 12
                : 6895-6911
                Article
                10.1118/1.4934830
                26632046
                20803ab2-accf-4980-81bf-ec169f702919
                © 2015

                http://doi.wiley.com/10.1002/tdm_license_1

                http://onlinelibrary.wiley.com/termsAndConditions

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article