      • Record: found
      • Abstract: found
      • Article: not found

      Effect of partial crystallization on the mechanical properties and cytotoxicity of bioactive glass from the 3CaO.P(2)O(5)-SiO(2)-MgO system.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of this study is to report on the development and characterization of bioactive glass and glass-ceramics from the 3CaO.P(2)O(5)-SiO(2)-MgO-system, using different degrees of cristallinity for applications as an implant material. A methodology was proposed to induce crystallization of phases. Bioglass samples of the nominal composition (wt %) 57.75 CaO.P(2)O(5)-30 SiO(2)-17.25MgO were heat treated at temperatures ranging from 700 to 1100°C for 4h. The findings from the research illustrate how partial crystallization and phase transformations modified the microstructure of the based glassy material, resulting in improved mechanical properties. The maximum gain was measured for samples treated at 975°C, having a hardness of 6.2GPa, an indentation fracture toughness of 1.7MPam(1/2) and a bending strength of 120MPa, representing an increase of 30, 55 and 70%, respectively, when compared to the nucleated glass. The highest elastic modulus of about 130GPa was determined for samples treated at 1100°C. As a preliminary biological evaluation, "in vitro" cytotoxicity tests were realized to determine the cytotoxic level of the materials, using the neutral red uptake method with NCTC clones L929 from the American Type Culture Collection (ATCC) bank. On the other hand, no significant influence of the partial crystallization on cytotoxicity was observed. The results provide support for implant materials based on the 3CaO.P(2)O(5)-SiO(2)-MgO-system.

          Related collections

          Author and article information

          Journal
          J Mech Behav Biomed Mater
          Journal of the mechanical behavior of biomedical materials
          Elsevier BV
          1878-0180
          1878-0180
          Oct 2012
          : 14
          Affiliations
          [1 ] EEL-USP, Escola de Engenharia de Lorena da Universidade de São Paulo, Polo Urbo-Industrial, Gleba AI-6, s/n, Mondesir, PC 116, Lorena (SP), Brazil. ju_daguano@yahoo.com.br
          Article
          S1751-6161(12)00150-6
          10.1016/j.jmbbm.2012.04.024
          22975418
          20b960f7-2776-4cb7-a763-d8cf893b162b
          History

          Comments

          Comment on this article