41
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Supraclavicular Approach to Ultrasound-Guided Brachiocephalic Vein Cannulation in Children and Neonates

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The correct choice of intra vascular access in critically ill neonates should be individualized depending on the type and duration of therapy, gestational and chronological age, weight and/or size, diagnosis, clinical status, and venous system patency. Accordingly, there is an ongoing demand for optimization of catheterization. Recently, the use of ultrasound (US)-guided cannulation of the subclavian vein (SCV) has been described in children and neonates. This article gives an overview of the current use of US for achieving central venous catheter placement in the SCV or the brachiocephalic vein (BCV) in neonates. More than 1,250 catheters have been reported inserted in children and neonates for a cumulated success rate of 98.4% and the complication rate is reported to be low. The technical aspects of various approaches are discussed, and we offer our recommendation of an US-guided technique for SCV and BCV cannulation based on our experience in a large NICU setting. Although the cannulation the SCV or BCV does not substitute the use of peripherally inserted central catheters or umbilical venous central catheters in neonates, it is a feasible route in very small children who are in need of a large caliber central venous access.

          Related collections

          Most cited references48

          • Record: found
          • Abstract: found
          • Article: not found

          International evidence-based recommendations on ultrasound-guided vascular access.

          To provide clinicians with an evidence-based overview of all topics related to ultrasound vascular access. An international evidence-based consensus provided definitions and recommendations. Medical literature on ultrasound vascular access was reviewed from January 1985 to October 2010. The GRADE and the GRADE-RAND methods were utilised to develop recommendations. The recommendations following the conference suggest the advantage of 2D vascular screening prior to cannulation and that real-time ultrasound needle guidance with an in-plane/long-axis technique optimises the probability of needle placement. Ultrasound guidance can be used not only for central venous cannulation but also in peripheral and arterial cannulation. Ultrasound can be used in order to check for immediate and life-threatening complications as well as the catheter's tip position. Educational courses and training are required to achieve competence and minimal skills when cannulation is performed with ultrasound guidance. A recommendation to create an ultrasound curriculum on vascular access is proposed. This technique allows the reduction of infectious and mechanical complications. These definitions and recommendations based on a critical evidence review and expert consensus are proposed to assist clinicians in ultrasound-guided vascular access and as a reference for future clinical research.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Ultrasonic locating devices for central venous cannulation: meta-analysis.

            To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVENTION REVIEWED: Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation. Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation. 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38). Evidence supports the use of two dimensional ultrasonography for central venous cannulation.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization.

              Central venous catheters (CVCs) can help with diagnosis and treatment of the critically ill. The catheter may be placed in a large vein in the neck (internal jugular vein), upper chest (subclavian vein) or groin (femoral vein). Whilst this is beneficial overall, inserting the catheter risks arterial puncture and other complications and should be performed with as few attempts as possible. Traditionally, anatomical 'landmarks' on the body surface were used to find the correct place in which to insert catheters, but ultrasound imaging is now available. A Doppler mode is sometimes used to supplement plain 'two-dimensional' ultrasound.
                Bookmark

                Author and article information

                Contributors
                URI : http://frontiersin.org/people/u/436554
                URI : http://frontiersin.org/people/u/447429
                URI : http://frontiersin.org/people/u/436732
                URI : http://frontiersin.org/people/u/458285
                URI : http://frontiersin.org/people/u/291281
                Journal
                Front Pediatr
                Front Pediatr
                Front. Pediatr.
                Frontiers in Pediatrics
                Frontiers Media S.A.
                2296-2360
                05 October 2017
                2017
                : 5
                : 211
                Affiliations
                [1] 1Pediatric and Neonatal Intensive Care Unit, Paris South University Hospitals, Le Kremlin-Bicêtre, Assistance Publique Hôpitaux de Paris , Paris, France
                [2] 2Institute of Integrative Biology of the Cell, CNRS, CEA, University of Paris Sud, Paris Saclay University , Gif-sur-Yvette, France
                Author notes

                Edited by: Cecile Tissot, Clinique des Grangettes, Switzerland

                Reviewed by: Kavita Morparia, Newark Beth Israel Medical Center, United States; Michael Leighton Forbes, Akron Children’s Hospital, United States

                *Correspondence: Pierre Tissieres, pierre.tissieres@ 123456aphp.fr

                These authors have contributed equally to this work.

                Specialty section: This article was submitted to Pediatric Critical Care, a section of the journal Frontiers in Pediatrics

                Article
                10.3389/fped.2017.00211
                5633682
                28180126
                20cb9f7e-c2ac-47c6-b9ad-70b9f160c143
                Copyright © 2017 Merchaoui, Lausten-Thomsen, Pierre, Ben Laiba, Le Saché and Tissieres.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 03 May 2017
                : 19 September 2017
                Page count
                Figures: 7, Tables: 1, Equations: 0, References: 53, Pages: 10, Words: 7376
                Categories
                Pediatrics
                Review

                central venous catheter,ultrasonography,doppler,color,children,neonatology,pediatric intensive care

                Comments

                Comment on this article

                scite_

                Similar content196

                Cited by17

                Most referenced authors535