7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Impact of body tilt on the central aortic pressure pulse

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The present work was undertaken to investigate, in young healthy volunteers, the relationships between the forward propagation times of arterial pressure waves and the timing of reflected waves observable on the aortic pulse, in the course of rapid changes in body position. 20 young healthy subjects, 10 men, and 10 women, were examined on a tilt table at two different tilt angles, −10° (Head-down) and + 45° (Head-up). In each position, carotid-femoral ( T cf) and carotid-tibial forward propagation times ( T ct) were measured with the Complior device. In each position also, the central aortic pressure pulse was recorded with radial tonometry, using the SphygmoCor device and a generalized transfer function, so as to evaluate the timing of reflected waves reaching the aorta in systole (onset of systolic reflected wave, sT1r) and diastole (mean transit time of diastolic reflected wave, dMTT). The position shift from Head-up to Head-down caused a massive increase in both T ct (women from 130 ± 10 to 185 ± 18 msec P < 0.001, men from 136 ± 9 to 204 ± 18 msec P < 0.001) and dMTT (women from 364 ± 35 to 499 ± 33 msec P < 0.001, men from 406 ± 22 to 553 ± 21 msec P < 0.001). Mixed model regression showed that the changes in T ct and dMTT observed between Head-up and Head-down were tightly coupled (regression coefficient 2.1, 95% confidence interval 1.9–2.3, P < 0.001). These results strongly suggest that the diastolic waves observed on central aortic pulses reconstructed from radial tonometric correspond at least in part to reflections generated in the lower limbs.

          Related collections

          Most cited references44

          • Record: found
          • Abstract: found
          • Article: not found

          Mechanical factors in arterial aging: a clinical perspective.

          The human arterial system in youth is beautifully designed for its role of receiving spurts of blood from the left ventricle and distributing this as steady flow through peripheral capillaries. Central to such design is "tuning" of the heart to arterial tree; this minimizes aortic pressure fluctuations and confines flow pulsations to the larger arteries. With aging, repetitive pulsations (some 30 million/year) cause fatigue and fracture of elastin lamellae of central arteries, causing them to stiffen (and dilate), so that reflections return earlier to the heart; in consequence, aortic systolic pressure rises, diastolic pressure falls, and pulsations of flow extend further into smaller vessels of vasodilated organs (notably the brain and kidney). Stiffening leads to increased left ventricular (LV) load with hypertrophy, decreased capacity for myocardial perfusion, and increased stresses on small arterial vessels, particularly of brain and kidney. Clinical manifestations are a result of diastolic LV dysfunction with dyspnea, predisposition to angina, and heart failure, and small vessel degeneration in brain and kidney with intellectual deterioration and renal failure. While aortic stiffening is the principal cause of cardiovascular disease with age in persons who escape atherosclerotic complications, it is not a specific target for therapy. The principal target is the smooth muscle in distributing arteries, whose relaxation has little effect on peripheral resistance but causes substantial reduction in the magnitude of wave reflection. Such relaxation is achieved through regular exercise and with the vasodilating drugs that are used in modern treatment of hypertension and cardiac failure.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Computation of aortic flow from pressure in humans using a nonlinear, three-element model.

            We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age-dependent, aortic pressure-area relationship (G. J. Langewouters et al. J. Biomech. 17:425-435, 1984). Peripheral resistance was predicted from mean pressure and model mean flow. Model flow pulsations from aortic pressure showed the visual aspects of an aortic flow curve. For evaluation we compared model mean flow from radial arterial pressure with thermodilution cardiac output estimations, 76 times, in eight open heart surgical patients. The pooled mean difference was +7%, the SD 22%. After using one comparison per patient to calibrate the model, however, we followed quantitative changes in cardiac output that occurred either during changes in the state of the patient or subsequent to vasoactive drugs. The mean deviation from thermodilution cardiac output was +2%, the SD 8%. Given these small errors the method could monitor cardiac output continuously.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function.

              Central aortic pressures and waveform convey important information about cardiovascular status, but direct measurements are invasive. Peripheral pressures can be measured noninvasively, and although they often differ substantially from central pressures, they may be mathematically transformed to approximate the latter. We tested this approach, examining intersubject and intrasubject variability and the validity of using a single averaged transformation, which would enhance its applicability. Invasive central aortic pressure by micromanometer and radial pressure by automated tonometry were measured in 20 patients at steady state and during hemodynamic transients (Valsalva maneuver, abdominal compression, nitroglycerin, or vena caval obstruction). For each patient, transfer functions (TFs) between aortic and radial pressures were calculated by parametric model and results averaged to yield individual TFs. A generalized TF was the average of individual functions. TFs varied among patients, with coefficients of variation for peak amplitude and frequency at peak amplitude of 24.9% and 16.9%, respectively. Intrapatient TF variance with altered loading (> 20% variation in peak amplitude) was observed in 28.5% of patients. Despite this, the generalized TF estimated central arterial pressures to < or = 0.2 +/- 3.8 mm Hg error, arterial compliance to 6 +/- 7% accuracy, and augmentation index to within -7% points (30 +/- 45% accuracy). Individual TFs were only marginally superior to the generalized TF for reconstructing central pressures. Central aortic pressures can be accurately estimated from radial tonometry with the use of a generalized TF. The reconstructed waveform can provide arterial compliance estimates but may underestimate the augmentation index because the latter requires greater fidelity reproduction of the wave contour.
                Bookmark

                Author and article information

                Journal
                Physiol Rep
                Physiol Rep
                phy2
                Physiological Reports
                BlackWell Publishing Ltd (Oxford, UK )
                2051-817X
                2051-817X
                April 2015
                12 April 2015
                : 3
                : 4
                : e12360
                Affiliations
                [1 ]Division de Physiopathologie clinique, Centre Hospitalier Universitaire Vaudois, University of Lausanne Lausanne, Switzerland
                [2 ]Service de Médecine intensive adulte, Centre Hospitalier Universitaire Vaudois, University of Lausanne Lausanne, Switzerland
                Author notes
                Correspondence François Feihl, 2 chemin de Richesson, CH - 1000 Lausanne 26, Switzerland., Tel: +41 21 784 38 24, E-mail: ffeihl@ 123456gmail.com

                Funding Information The study was funded by the Centre Hospitalier Universitaire Vaudois.

                Article
                10.14814/phy2.12360
                4425966
                25862096
                20d1bbfe-8669-4bd2-aa28-66818dad4b15
                © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

                This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

                History
                : 21 January 2015
                : 05 March 2015
                : 07 March 2015
                Categories
                Original Research

                aorta,blood pressure,diastole,hemodynamics,posture,pulse wave analysis

                Comments

                Comment on this article