      Arterial Remodeling After Coronary Angioplasty : A Serial Intravascular Ultrasound Study

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background Restenosis occurs after 30% to 50% of transcatheter coronary procedures; however, the natural history and pathophysiology of restenosis are still incompletely understood.

          Methods and Results Serial (postintervention and follow-up) intravascular ultrasound imaging was used to study 212 native coronary lesions in 209 patients after percutaneous transluminal coronary angioplasty, directional coronary atherectomy, rotational atherectomy, or excimer laser angioplasty. The external elastic membrane (EEM) and lumen cross-sectional areas (CSA) were measured; plaque plus media (P+M) CSA was calculated as EEM minus lumen CSA. The anatomic slice selected for serial analysis had an axial location within the target lesion at the smallest follow-up lumen CSA. At follow-up, 73% of the decrease in lumen (from 6.6±2.5 to 4.0±3.7 mm 2 , P <.0001) was due to a decrease in EEM (from 20.1±6.4 to 18.2±6.4 mm 2 , P <.0001); 27% was due to an increase in P+M (from 13.5±5.5 to 14.2±5.4 mm 2 , P <.0001). ΔLumen CSA correlated more strongly with ΔEEM CSA ( r =.751, P <.0001) than with ΔP+M CSA ( r =.284, P <.0001). ΔEEM was bidirectional; 47 lesions (22%) showed an increase in EEM. Despite a greater increase in P+M (1.5±2.5 versus 0.5±2.0 mm 2 , P =.0009), lesions exhibiting an increase in EEM had (1) no change in lumen (−0.1±3.3 versus 3.6±2.3 mm 2 , P <.0001), (2) a reduced restenosis rate (26% versus 62%, P <.0001), and (3) a 49% frequency of late lumen gain (versus 1%, P <.0001) compared with lesions with no increase in EEM.

          Conclusions Restenosis appears to be determined primarily by the direction and magnitude of vessel wall remodeling (ΔEEM). An increase in EEM is adaptive, whereas a decrease in EEM contributes to restenosis.

          Related collections

          Most cited references63

          • Record: found
          • Abstract: found
          • Article: not found

          Increased expression of matrix metalloproteinases and matrix degrading activity in vulnerable regions of human atherosclerotic plaques.

          Dysregulated extracellular matrix (ECM) metabolism may contribute to vascular remodeling during the development and complication of human atherosclerotic lesions. We investigated the expression of matrix metalloproteinases (MMPs), a family of enzymes that degrade ECM components in human atherosclerotic plaques (n = 30) and in uninvolved arterial specimens (n = 11). We studied members of all three MMP classes (interstitial collagenase, MMP-1; gelatinases, MMP-2 and MMP-9; and stromelysin, MMP-3) and their endogenous inhibitors (TIMPs 1 and 2) by immunocytochemistry, zymography, and immunoprecipitation. Normal arteries stained uniformly for 72-kD gelatinase and TIMPs. In contrast, plaques' shoulders and regions of foam cell accumulation displayed locally increased expression of 92-kD gelatinase, stromelysin, and interstitial collagenase. However, the mere presence of MMP does not establish their catalytic capacity, as the zymogens lack activity, and TIMPs may block activated MMPs. All plaque extracts contained activated forms of gelatinases determined zymographically and by degradation of 3H-collagen type IV. To test directly whether atheromata actually contain active matrix-degrading enzymes in situ, we devised a method which allows the detection and microscopic localization of MMP enzymatic activity directly in tissue sections. In situ zymography revealed gelatinolytic and caseinolytic activity in frozen sections of atherosclerotic but not of uninvolved arterial tissues. The MMP inhibitors, EDTA and 1,10-phenanthroline, as well as recombinant TIMP-1, reduced these activities which colocalized with regions of increased immunoreactive MMP expression, i.e., the shoulders, core, and microvasculature of the plaques. Focal overexpression of activated MMP may promote destabilization and complication of atherosclerotic plaques and provide novel targets for therapeutic intervention.
            • Record: found
            • Abstract: found
            • Article: not found

            A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.

            Coronary-stent placement is a new technique in which a balloon-expandable, stainless-steel, slotted tube is implanted at the site of a coronary stenosis. The purpose of this study was to compare the effects of stent placement and standard balloon angioplasty on angiographically detected restenosis and clinical outcomes. We randomly assigned 410 patients with symptomatic coronary disease to elective placement of a Palmaz-Schatz stent or to standard balloon angioplasty. Coronary angiography was performed at base line, immediately after the procedure, and six months later. The patients who underwent stenting had a higher rate of procedural success than those who underwent standard balloon angioplasty (96.1 percent vs. 89.6 percent, P = 0.011), a larger immediate increase in the diameter of the lumen (1.72 +/- 0.46 vs. 1.23 +/- 0.48 mm, P < 0.001), and a larger luminal diameter immediately after the procedure (2.49 +/- 0.43 vs. 1.99 +/- 0.47 mm, P < 0.001). At six months, the patients with stented lesions continued to have a larger luminal diameter (1.74 +/- 0.60 vs. 1.56 +/- 0.65 mm, P = 0.007) and a lower rate of restenosis (31.6 percent vs. 42.1 percent, P = 0.046) than those treated with balloon angioplasty. There were no coronary events (death; myocardial infarction; coronary-artery bypass surgery; vessel closure, including stent thrombosis; or repeated angioplasty) in 80.5 percent of the patients in the stent group and 76.2 percent of those in the angioplasty group (P = 0.16). Revascularization of the original target lesion because of recurrent myocardial ischemia was performed less frequently in the stent group than in the angioplasty group (10.2 percent vs. 15.4 percent, P = 0.06). In selected patients, placement of an intracoronary stent, as compared with balloon angioplasty, results in an improved rate of procedural success, a lower rate of angiographically detected restenosis, a similar rate of clinical events after six months, and a less frequent need for revascularization of the original coronary lesion.
              • Record: found
              • Abstract: found
              • Article: not found

              Compensatory enlargement of human atherosclerotic coronary arteries.

              Whether human coronary arteries undergo compensatory enlargement in the presence of coronary disease has not been clarified. We studied histologic sections of the left main coronary artery in 136 hearts obtained at autopsy to determine whether atherosclerotic human coronary arteries enlarge in relation to plaque (lesion) area and to assess whether such enlargement preserves the cross-sectional area of the lumen. The area circumscribed by the internal elastic lamina (internal elastic lamina area) was taken as a measure of the area of the arterial lumen if no plaque had been present. The internal elastic lamina area correlated directly with the area of the lesion (r = 0.44, P less than 0.001), suggesting that coronary arteries enlarge as lesion area increases. Regression analysis yielded the following equation: Internal elastic lamina area = 9.26 + 0.88 (lesion area) + 0.026 (age) + 0.005 (heart weight). The correlation coefficient for the lesion area was significant (P less than 0.001), whereas the correlation coefficients for age and heart weight were not. The lumen area did not decrease in relation to the percentage of stenosis (lesion area/internal elastic lamina area X 100) for values between zero and 40 percent but did diminish markedly and in close relation to the percentage of stenosis for values above 40 percent (r = -0.73, P less than 0.001). We conclude that human coronary arteries enlarge in relation to plaque area and that functionally important lumen stenosis may be delayed until the lesion occupies 40 percent of the internal elastic lamina area. The preservation of a nearly normal lumen cross-sectional area despite the presence of a large plaque should be taken into account in evaluating atherosclerotic disease with use of coronary angiography.

                Author and article information

                Journal
                Circulation
                Circulation
                Ovid Technologies (Wolters Kluwer Health)
                0009-7322
                1524-4539
                July 1996
                July 1996
                : 94
                : 1
                : 35-43
                Affiliations
                [1 ]From the Intravascular Ultrasound Imaging and Cardiac Catheterization Laboratories, the Washington Hospital Center, Washington, DC.
                Article
                10.1161/01.CIR.94.1.35
                8964115
                2160408a-61fc-42d0-accc-7824ad2ecacd
                © 1996