      A reconfigurable continuous-flow fluidic routing fabric using a modular, scalable primitive

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Using a single primitive (A., B.) we created an algorithmically scalable (D.) reconfigurable routing fabric (E.) for continuous-flow microfluidic devices capable of arbitrary routing.

          Abstract

          Microfluidic devices, by definition, are required to move liquids from one physical location to another. Given a finite and frequently fixed set of physical channels to route fluids, a primitive design element that allows reconfigurable routing of that fluid from any of n input ports to any n output ports will dramatically change the paradigms by which these chips are designed and applied. Furthermore, if these elements are “regular” regarding their design, the programming and fabrication of these elements becomes scalable. This paper presents such a design element called a transposer. We illustrate the design, fabrication and operation of a single transposer. We then scale this design to create a programmable fabric towards a general-purpose, reconfigurable microfluidic platform analogous to the Field Programmable Gate Array (FPGA) found in digital electronics.

          Related collections

          Most cited references31

          • Record: found
          • Abstract: found
          • Article: not found

          Microfluidic large-scale integration.

          We developed high-density microfluidic chips that contain plumbing networks with thousands of micromechanical valves and hundreds of individually addressable chambers. These fluidic devices are analogous to electronic integrated circuits fabricated using large-scale integration. A key component of these networks is the fluidic multiplexor, which is a combinatorial array of binary valve patterns that exponentially increases the processing power of a network by allowing complex fluid manipulations with a minimal number of inputs. We used these integrated microfluidic networks to construct the microfluidic analog of a comparator array and a microfluidic memory storage device whose behavior resembles random-access memory.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Continuous flow separations in microfluidic devices.

            Biochemical sample mixtures are commonly separated in batch processes, such as filtration, centrifugation, chromatography or electrophoresis. In recent years, however, many research groups have demonstrated continuous flow separation methods in microfluidic devices. Such separation methods are characterised by continuous injection, real-time monitoring, as well as continuous collection, which makes them ideal for combination with upstream and downstream applications. Importantly, in continuous flow separation the sample components are deflected from the main direction of flow, either by means of a force field (electric, magnetic, acoustic, optical etc.), or by intelligent positioning of obstacles in combination with laminar flow profiles. Sample components susceptible to deflection can be spatially separated. A large variety of methods has been reported, some of these are miniaturised versions of larger scale methods, others are only possible in microfluidic regimes. Researchers now have a diverse toolbox to choose from and it is likely that continuous flow methods will play an important role in future point-of-care or in-the-field analysis devices.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Free flow acoustophoresis: microfluidic-based mode of particle and cell separation.

              A novel method, free flow acoustophoresis (FFA), capable of continuous separation of mixed particle suspensions into multiple outlet fractions is presented. Acoustic forces are utilized to separate particles based on their size and density. The method is shown to be suitable for both biological and nonbiological suspended particles. The microfluidic separation chips were fabricated using conventional microfabrication methods. Particle separation was accomplished by combining laminar flow with the axial acoustic primary radiation force in an ultrasonic standing wave field. Dissimilar suspended particles flowing through the 350-microm-wide channel were thereby laterally translated to different regions of the laminar flow profile, which was split into multiple outlets for continuous fraction collection. Using four outlets, a mixture of 2-, 5-, 8-, and 10-microm polystyrene particles was separated with between 62 and 94% of each particle size ending up in separate fractions. Using three outlets and three particle sizes (3, 7, and 10 microm) the corresponding results ranged between 76 and 96%. It was also proven possible to separate normally acoustically inseparable particle types by manipulating the density of the suspending medium with cesium chloride. The medium manipulation, in combination with FFA, was further used to enable the fractionation of red cells, platelets, and leukocytes. The results show that free flow acoustophoresis can be used to perform complex separation tasks, thereby offering an alternative to expensive and time-consuming methods currently in use.
                Bookmark

                Author and article information

                Journal
                LCAHAM
                Lab on a Chip
                Lab Chip
                Royal Society of Chemistry (RSC)
                1473-0197
                1473-0189
                2016
                2016
                : 16
                : 14
                : 2730-2741
                Affiliations
                [1 ]Boston University Department of Electrical and Computer Engineering
                [2 ]Boston
                [3 ]USA
                [4 ]Biological Design Center
                Article
                10.1039/C6LC00477F
                225db602-5e8c-4790-aaa4-2642819cda28
                © 2016
                History

                Comments

                Comment on this article