17
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Assessment of Uncertainties for the NIST 1016 mm Guarded-Hot-Plate Apparatus: Extended Analysis for Low-Density Fibrous-Glass Thermal Insulation

      research-article

      Read this article at

      ScienceOpenPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          An assessment of uncertainties for the National Institute of Standards and Technology (NIST) 1016 mm Guarded-Hot-Plate apparatus is presented. The uncertainties are reported in a format consistent with current NIST policy on the expression of measurement uncertainty. The report describes a procedure for determination of component uncertainties for thermal conductivity and thermal resistance for the apparatus under operation in either the double-sided or single-sided mode of operation. An extensive example for computation of uncertainties for the single-sided mode of operation is provided for a low-density fibrous-glass blanket thermal insulation. For this material, the relative expanded uncertainty for thermal resistance increases from 1 % for a thickness of 25.4 mm to 3 % for a thickness of 228.6 mm. Although these uncertainties have been developed for a particular insulation material, the procedure and, to a lesser extent, the results are applicable to other insulation materials measured at a mean temperature close to 297 K (23.9 °C, 75 °F). The analysis identifies dominant components of uncertainty and, thus, potential areas for future improvement in the measurement process. For the NIST 1016 mm Guarded-Hot-Plate apparatus, considerable improvement, especially at higher values of thermal resistance, may be realized by developing better control strategies for guarding that include better measurement techniques for the guard gap thermopile voltage and the temperature sensors.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: not found
          • Article: not found

          Guide to the Expression of Uncertainty in Measurement

            Bookmark
            • Record: found
            • Abstract: not found
            • Book: not found

            Statistics fort experimenters

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              DATAPLOT---an interactive high-level language for graphics, non-linear fitting, data analysis, and mathematics

                Bookmark

                Author and article information

                Contributors
                Journal
                J Res Natl Inst Stand Technol
                J Res Natl Inst Stand Technol
                JRES
                Journal of Research of the National Institute of Standards and Technology
                [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
                1044-677X
                2165-7254
                Jan-Feb 2010
                01 February 2010
                : 115
                : 1
                : 23-59
                Affiliations
                National Institute of Standards and Technology, Gaithersburg, MD 20899-8632
                Article
                v115.n01.a04
                4548527
                22c69d72-faf4-430c-8bbe-379a0645d6c2
                Copyright @ 2010

                The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.

                History
                : 03 November 2009
                Funding
                Funded by: National Institute of Standards and Technology
                Award ID: 9999-NIST
                Categories
                Article

                building technology,fibrous glass blanket,guarded hot plate,thermal conductivity,thermal insulation,thermal resistance,uncertainty

                Comments

                Comment on this article