4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Acute effects of hemodialysis on lung function in patients with end-stage renal disease.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Impaired lung function in hemodialysis patients may be caused by an underlying pulmonary disease; however, the impact of uremia and the effects of dialysis treatment are not well understood. Our investigation aimed to characterize the acute effects of bicarbonate hemodialysis using membranes differing in biocompatibility on various parameters of lung function in unselected uremic patients maintained on regular hemodialysis. Fourteen clinically stable hemodialysis patients without acute lung disease were included in the study. Restrictive lung disease was present in eight of 14 cases and obstructive lung disease in one patient. A cellulose dialyzer membrane and a synthetic high-flux dialyzer membrane were each tested twice (two sessions one week apart). Spirometry (VCmax, FEV1, FEF(25-75%), PEF) was carried out before and after hemodialysis. Resistance was determined with the interrupter technique and with the impulse oscillation system (R5Hz, R20Hz) before, during and after hemodialysis. Our comparative investigation of two dialyzer membranes found that bioincompatibility of dialysis had no acute adverse effects on lung function in our heterogeneous population of dialysis patients. None of our patients experienced bronchoconstriction or aggravation of obstructive lung disease as a result of poor biocompatibility of the dialyzer membrane. Spirometric data and resistance measurements by two different methods showed no relevant changes during the dialysis procedure. There was no correlation between lung function parameters and interdialytic changes in body weight or duration on hemodialysis. Regardless of the membrane used, the hemodialysis procedure does not acutely affect lung function in uremic patients on maintenance hemodialysis. Hemodialysis is a safe procedure even in uremic patients with pre-existing lung disease.

          Related collections

          Author and article information

          Journal
          Wien. Klin. Wochenschr.
          Wiener klinische Wochenschrift
          Springer Nature America, Inc
          0043-5325
          0043-5325
          Mar 2006
          : 118
          : 3-4
          Affiliations
          [1 ] Division of Pneumology, Department of Medicine, Medizinische Klinik Innenstadt, University of Munich, Germany. lang_susanne@hotmail.com
          Article
          10.1007/s00508-006-0564-7
          16703255
          236b5837-6794-4c1b-a1a4-8a5ffc992562
          History

          Comments

          Comment on this article