80
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form

      research-article

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, with a correlation coefficient of 1 and 0.9999 for PCM and CF, respectively, over the concentration ranges of 15–300 μg/mL (PCM) and 2.5–50 μg/mL (CF). The retention time ( t R) was found to be 2.6 ± 0.001 and 3.5 ± 0.002 min for PCM and CF, respectively. Extensive stress degradation studies were conducted by subjecting the analytes to various stress conditions of acidic and alkaline hydrolysis as well as oxidative, photolytic, and heat degradations. The method was found to efficiently separate the analytes' peaks from that of the degradation products, without any variation in their retention times. The relative standard deviation (RSD) values of all recoveries for PCM and CF were less than 1.3%. The method was found to be suitable for routine analysis of PCM and CF in pharmaceutical dosage form.

          Related collections

          Author and article information

          Journal
          1326
          Acta Chromatographica
          Acta Chromatographica
          Akadémiai Kiadó
          2083-5736
          June 2019
          : 31
          : 2
          : 85-91
          Affiliations
          [1 ]Discipline of Pharmaceutical Technology, School of Pharmaceutical Sciences, Universiti Sains Malaysia , 11800 USM, Penang, Malaysia
          [2 ]Department of Pharmaceutics and Pharmaceutical Microbiology, Faculty of Pharmaceutical Sciences, Usmanu Danfodiyo University , P.M.B. 2346, Sokoto, Nigeria
          Author notes
          Article
          10.1556/1326.2018.00354
          251ebd93-8a0b-4b90-86f9-396f1fa40553
          © 2018 The Author(s)

          This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License ( https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and reproduction in any medium for non-commercial purposes, provided the original author and source are credited, a link to the CC License is provided, and changes - if any - are indicated.

          History
          : 17 July 2017
          : 20 December 2017
          : 14 March 2018
          Page count
          Pages: 7
          Categories
          Original Research Paper

          Materials properties,Nanomaterials,Chemistry,Nanotechnology,Analytical chemistry,Thin films & surfaces
          stress degradation study,caffeine,Stability-indicating HPLC,paracetamol,simultaneous determination,fixed-dose combination tablets

          Comments

          Comment on this article