      Fast and furious: a retrospective study of catheter-associated bloodstream infections with internal jugular nontunneled hemodialysis catheters at a tropical center

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Nontunneled hemodialysis catheters (NTHCs) remain the preferred vascular access at hemodialysis (HD) initiation in developing countries. We studied the incidence, risk factors and microbiological spectrum of jugular NTHC-associated bloodstream infections (CABSIs) at a tertiary care center in South Asia.

          Methods

          In this retrospective cohort study, all adult (≥18 years) incident patients who underwent jugular NTHC insertion for HD between January 2016 and June 2017, had no prior history of temporary vascular access insertion and were followed up for ≥14 days were included.

          Results

          A total of 897 patients underwent NTHC insertion during the study period and 169 patients fulfilled the inclusion criteria and contributed 7079 patient days of follow-up. CABSI incidence was 7.34 episodes per 1000 catheter days and median infection-free survival and time to CABSI were 96 and 24.5 days, respectively. In multivariate Cox regression analysis, immunosuppressive medication {hazard ratio [HR] 2.87 [95% confidence interval (CI) 1.09–7.55]; P = 0.033} and intravenous cefazolin use [HR 0.51 (95% CI 0.28–0.94); P = 0.031] was independently associated with CABSI. The cumulative hazard of CABSI was 8.3, 13.3, 17.6 and 20.9% at Weeks 1, 2, 3 and 4, respectively. Gram-negative organisms were the most common etiological agents (54.7%) and 40.3% of CABSIs were caused by drug-resistant organisms. Gram-negative and Gram-positive CABSIs were associated with neutrophil left shift and higher procalcitonin compared with coagulase-negative staphylococcal CABSIs.

          Conclusion

          In South Asia, NTHC-associated CABSIs occur early and are predominantly Gram negative. We hypothesize that poor hygiene practices may play a role in this phenomenon.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique.

          Central venous access is an essential part of patient management in many clinical settings and is usually achieved with a blinded, external landmark-guided technique. The purpose of this study is to evaluate whether an ultrasound technique can improve on the traditional method. We prospectively evaluated an ultrasound-guided method in 302 patients undergoing internal jugular venous cannulation and compared the results with 302 patients in whom an external landmark-guided technique was used. Ultrasound was used exclusively in an additional 626 patients. Cannulation of the internal jugular vein was achieved in all patients (100%) using ultrasound and in 266 patients (88.1%) using the landmark-guided technique (p < 0.001). The vein was entered on the first attempt in 78% of patients using ultrasound and in 38% using the landmark technique (p < 0.001). Average access time (skin to vein) was 9.8 seconds (2-68 seconds) by the ultrasound approach and 44.5 seconds (2-1,000 seconds) by the landmark approach (p < 0.001). Using ultrasound, puncture of the carotid artery occurred in 1.7% of patients, brachial plexus irritation in 0.4%, and hematoma in 0.2%. In the external landmark group, puncture of the carotid artery occurred in 8.3% of patients (p < 0.001), brachial plexus irritation in 1.7% (p < 0.001), and hematoma in 3.3% (p < 0.001). Ultrasound-guided cannulation of the internal jugular vein significantly improves success rate, decreases access time, and reduces complication rate. These results suggest that this technique may be preferred in complicated cases or when access problems are anticipated.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            EPIBACDIAL: a multicenter prospective study of risk factors for bacteremia in chronic hemodialysis patients.

            Bacteremic infections are a major cause of mortality and morbidity in chronic hemodialysis patients. New developments in managing these patients (erythropoietin therapy, nasal mupirocin, long-term implanted catheters, and synthetic membranes) may have altered the epidemiologic patterns of bacteremia in dialysis patients. This multicenter prospective cross-sectional study was carried out to determine the current incidence of and risk factors for bacteremia in chronic hemodialysis patients in France. A total of 988 adults on chronic hemodialysis for 1 mo or longer was followed up prospectively for 6 mo in 19 French dialysis units. The factors associated with the development of at least one bacteremic episode over 6 mo were determined using the multivariate Cox proportional hazards model. Staphylococcus aureus (n=20) and coagulase-negative staphylococci (n=15) were responsible for most of the 51 bacteremic episodes recorded. The incidence of bacteremia was 0.93 episode per 100 patient-months. Four risk factors for bacteremia were identified: (1) vascular access (catheter versus fistula: RR=7.6; 95% CI, 3.7 to 15.6); (2) history of bacteremia (> or =2 versus no previous episode: RR=7.3; 95% CI, 3.2 to 16.4); (3) immunosuppressive therapy (current versus no: RR=3.0; 95% CI, 1.0 to 6.1); and (4) corpuscular hemoglobin (per 1 g/dl increment: RR=0.7; 95% CI, 0.6 to 0.9). Catheters, especially long-term implanted catheters, were found to be the leading risk factor of bacteremia in chronic hemodialysis patients. There was a trend toward recurrence of bacteremia that was not associated with chronic staphylococcal nasal carriage. Synthetic membranes were not associated with a lower risk of bacteremia in this population of well dialyzed patients, but anemia linked to resistance to erythropoietin appeared to be a possible risk factor for bacteremia.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: a prospective study.

              Uncuffed, nontunneled hemodialysis catheters remain the preferred means to gain immediate access to the circulation for hemodialysis. Bacteremia is the primary complication that limits their use. The risk of bacteremia by site of insertion and duration of use has not been well studied. Two hundred eighteen consecutive patients who required a temporary hemodialysis catheter were prospectively followed. Catheters were placed at 318 new insertion sites and remained in use for a total of 6235 days. The incidence of bacteremia was 5.4% after three weeks of placement in internal jugular vein and 10.7% after one week in femoral vein [relative risk for bacteremia 3.1 (95% CI, 1.8 to 5.2)]. The incidence of bacteremia was 1.9% one day after the onset of an exit site infection but increased to 13.4% by the second day if the catheter was not removed. Guidewire exchange for malfunction and patient factors did not significantly affect the risk of bacteremia. Internal jugular catheters may be left in place for up to three weeks without a high risk of bacteremia, but femoral catheters in bed-bound patients should be removed after one week. Catheter exchanges over a guidewire for catheter malfunction do not increase bacteremia rates. Temporary catheters should be removed immediately if an exit site infection occurs.
                Bookmark

                Author and article information

                Journal
                Clin Kidney J
                Clin Kidney J
                ckj
                Clinical Kidney Journal
                Oxford University Press
                2048-8505
                2048-8513
                October 2019
                05 February 2019
                05 February 2019
                : 12
                : 5
                : 737-744
                Affiliations
                [1 ]Department of Nephrology, Christian Medical College Hospital , Vellore, Tamil Nadu, India
                [2 ]Department of Microbiology, Christian Medical College Hospital , Vellore, Tamil Nadu, India
                Author notes
                Correspondence and offprint requests to: Anna T. Valson; E-mail: ceruleus@ 123456gmail.com
                Author information
                http://orcid.org/0000-0002-3439-4250
                Article
                sfy138
                10.1093/ckj/sfy138
                6768464
                31583098
                284813c8-de8d-4a62-845e-acb5b100dffa
                © The Author(s) 2019. Published by Oxford University Press on behalf of ERA-EDTA.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com

                History
                : 03 August 2018
                Page count
                Pages: 8
                Categories
                Dialysis

                Nephrology
                catheter-related infections/epidemiology,catheter-related infections/microbiology,hemodialysis,nontunneled hemodialysis catheters,south asia

                Comments