10
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      I -123 metaiodobenzylguanidine imaging for predicting ventricular arrhythmia in heart failure patients

      review-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Compared to antiarrhythmic drugs, implantable cardioverter defibrillator (ICD) leads to a more significant improvement in preventing ventricular arrhythmia in heart failure patients. However, an important question has been raised that how to select appropriate patients for ICD therapy. I-123 metaiodobenzylguanidine (MIBG) planar and SPECT imaging have shown great potentials to predict ventricular arrhythmia in heart failure patients by assessing the abnormalities of the sympathetic nervous system. Clinical trials demonstrated that several parameters measured from I-123 MIBG planar and SPECT imaging, such as heart-to-mediastinum ratio, washout rate, defect score, and innervation/perfusion mismatch, predicted ventricular arrhythmias in heart failure patients. This paper introduces the current practice of ICD therapy and reviews the technical background of I-123 MIBG planar and SPECT imaging and their clinical data in predicting ventricular arrhythmia.

          Related collections

          Most cited references118

          • Record: found
          • Abstract: not found
          • Article: not found

          ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2008: the Task Force for the Diagnosis and Treatment of Acute and Chronic Heart Failure 2008 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association of the ESC (HFA) and endorsed by the European Society of Intensive Care Medicine (ESICM).

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Sudden cardiac death.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverter-defibrillator patients.

              The purpose of this study was to evaluate whether 123-iodine metaiodobenzylguanidine (123-I MIBG) imaging predicts ventricular arrhythmias causing appropriate implantable cardioverter-defibrillator (ICD) therapy (primary end point) and the composite of appropriate ICD therapy or cardiac death (secondary end point). Although cardiac sympathetic denervation is associated with ventricular arrhythmias, limited data are available on the predictive value of sympathetic nerve imaging with 123-I MIBG on the occurrence of arrhythmias. Before ICD implantation, patients underwent 123-I MIBG and myocardial perfusion imaging. Early and late 123-I MIBG (planar and single-photon emission computed tomography [SPECT]) imaging was performed to assess cardiac innervation (heart-to-mediastinum ratio, cardiac washout rate, and 123-I MIBG SPECT defect score). Stress-rest myocardial perfusion imaging was performed to assess myocardial infarction and perfusion abnormalities (perfusion defect scores). During follow-up, appropriate ICD therapy and cardiac death were documented. One-hundred sixteen heart failure patients referred for ICD therapy were enrolled. During a mean follow-up of 23 +/- 15 months, appropriate ICD therapy (primary end point) was documented in 24 (21%) patients and appropriate ICD therapy or cardiac death (secondary end point) in 32 (28%) patients. Late 123-I MIBG SPECT defect score was an independent predictor for both end points. Patients with a large late 123-I MIBG SPECT defect (summed score >26) showed significantly more appropriate ICD therapy (52% vs. 5%, p < 0.01) and appropriate ICD therapy or cardiac death (57% vs. 10%, p < 0.01) than patients with a small defect (summed score
                Bookmark

                Author and article information

                Journal
                J Biomed Res
                J Biomed Res
                JBR
                Journal of Biomedical Research
                Editorial Department of Journal of Biomedical Research
                1674-8301
                November 2013
                25 September 2013
                : 27
                : 6
                : 460-466
                Affiliations
                [1]Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA 30322, USA.
                Author notes
                []Corresponding author: Ji Chen, PhD, FACC, FASNC. Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1364 Clifton Rd NE, Atlanta, GA 30322, USA. Tel/Fax: 1-404-712-4024/1-404-727-3488, Email: jchen22@ 123456emory.edu .

                The authors reported no conflict of interests.

                Article
                jbr-27-06-460
                10.7555/JBR.27.20130137
                3841471
                2954d84b-c727-4ef8-b2ba-ea002a0ce287
                © 2013 by the Journal of Biomedical Research. All rights reserved.
                History
                : 4 September 2013
                : 16 September 2013
                Categories
                Invited Review

                heart failure,ventricular arrhythmia,implantable cardioverter defibrillator,i-123 metaiodobenzylguanidine (mibg)

                Comments

                Comment on this article