      A comparison of 4 epinephrine autoinjector delivery systems: usability and patient preference

      , ,
      Annals of Allergy, Asthma & Immunology
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Prefilled epinephrine autoinjectors are sometimes improperly used by patients, caregivers, and physicians. A user-centered design process led to the development of 2 prototype epinephrine autoinjectors (INT01 and INT02) that have a unidirectional perceived injection end, a self-retracting needle, and, with INT02, voice instructions to assist in guiding users through administration. To compare the usability and patient preference among 4 epinephrine autoinjectors: EpiPen, TwinJect, INT01, and INT02. A total of 48 participants were divided equally among 3 age groups: 7 to 10, 11 to 15, and 16 to 55 years. In each group, half had prior TwinJect or EpiPen training. In 1-hour sessions, without training, participants performed simulated-use testing under observation for all 4 epinephrine delivery systems. Usability (i.e., the ability to perform the manufacturer's labeled instructions), task completion time, and preferences were assessed and analyzed based on device, age, previous experience, sex, device malfunction, and testing order. More participants correctly followed all device instructions with INT02 (22 [46%]) than with INT01 (13 [27%]), EpiPen (6 [12%]), or TwinJect (0 [0%]). The difference among devices was significant (P < .01) after adjusting for device malfunctions and age group (the youngest age group [those aged 7-10 years] performed significantly worse than the other 2 groups). Prior experience, sex, and testing order did not significantly affect this measure. The first choice of overall preference was greater (P < .001) for INT02 (35 participants [73%]) vs. INT01 (7 participants [15%]), EpiPen (5 participants [10%]), and TwinJect (1 participant [2%]). The user-centered device design may have a significant impact on correct epinephrine autoinjector use and patient preference.

          Related collections

          Author and article information

          Journal
          Annals of Allergy, Asthma & Immunology
          Annals of Allergy, Asthma & Immunology
          Elsevier BV
          10811206
          February 2010
          February 2010
          : 104
          : 2
          : 172-177
          Article
          10.1016/j.anai.2009.11.023
          2892620
          20306821
          2a8700d5-c186-4953-862e-7a34f9326348
          © 2010

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article