6
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Falda en la TAVI - un embalaje sin peaje Translated title: Skirt in TAVI: a toll-free packaging

      editorial
      ,
      REC: Interventional Cardiology
      Sociedad Española de Cardiología

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references11

          • Record: found
          • Abstract: found
          • Article: not found

          Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients

          Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature.

            This study was designed to establish the incidence, impact, and predictors of post-transcatheter aortic valve replacement (TAVR) aortic regurgitation (AR). AR is an important limitation of TAVR with ill-defined predictors and unclear long-term impact on outcomes. Studies published between 2002 and 2012 with regard to TAVR were identified using an electronic search and reviewed using the random-effects model of DerSimonian and Laird. From 3,871 initial citations, 45 studies reporting on 12,926 patients (CoreValve [Medtronic CV Luxembourg S.a.r.l., Tolochenaz, Switzerland] n = 5,261 and Edwards valve [Edwards Lifesciences, Santa Ana, California] n = 7,279) were included in the analysis of incidence and outcomes of post-TAVR AR. The pooled estimate for moderate or severe AR post-TAVR was 11.7% (95% confidence interval [CI]: 9.6 to 14.1). Moderate or severe AR was more common with use of the CoreValve (16.0% vs. 9.1%, p = 0.005). The presence of moderate or severe AR post-TAVR increased mortality at 30 days (odds ratio: 2.95; 95% CI: 1.73 to 5.02) and 1 year (hazard ratio: 2.27; 95% CI: -1.84 to 2.81). Mild AR was also associated with an increased hazard ratio for mortality, 1.829 (95% CI: 1.005 to 3.329) that was overturned by sensitivity analysis. Twenty-five studies reported on predictors of post-TAVR AR. Implantation depth, valve undersizing, and Agatston calcium score (r = 0.47, p = 0.001) were identified as important predictors. Moderate or severe aortic regurgitation is common after TAVR and an adverse prognostic indicator of short- and long-term survival. Incidence of moderate or severe AR is higher with use of the CoreValve. Mild AR may be associated with increased long-term mortality. Therefore, every effort should be made to minimize AR by a comprehensive pre-procedural planning and meticulous procedural execution. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              2-Year Outcomes in Patients Undergoing Surgical or Self-Expanding Transcatheter Aortic Valve Replacement.

              The U.S. pivotal trial for the self-expanding valve found that among patients with severe aortic stenosis at increased risk for surgery, the 1-year survival rate was 4.9 percentage points higher in patients treated with a self-expanding transcatheter aortic valve bioprosthesis than in those treated with a surgical bioprosthesis.
                Bookmark

                Author and article information

                Journal
                recic
                REC: Interventional Cardiology
                REC Interv Cardiol ES
                Sociedad Española de Cardiología (Madrid, Madrid, Spain )
                2604-7306
                2604-7276
                September 2023
                : 5
                : 3
                : 165-166
                Affiliations
                [2] Barcelona orgnameCentro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV) España
                [3] Barcelona orgnameHospital Universitari Vall d'Hebron orgdiv1Servicio de Radiología Spain
                [1] Barcelona orgnameHospital Universitari Vall d'Hebron orgdiv1Servicio de Cardiología Spain
                Article
                S2604-73062023000300001 S2604-7306(23)00500300001
                10.24875/recic.m23000379
                2c3ed9f0-27cb-42f2-92e8-f1129e1814cd

                This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

                History
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 11, Pages: 2
                Product

                SciELO Spain

                Categories
                Editoriales

                Comments

                Comment on this article