      Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In mechanically ventilated patients with acute circulatory failure related to sepsis, we investigated whether the respiratory changes in arterial pressure could be related to the effects of volume expansion (VE) on cardiac index (CI). Forty patients instrumented with indwelling systemic and pulmonary artery catheters were studied before and after VE. Maximal and minimal values of pulse pressure (Pp(max) and Pp(min)) and systolic pressure (Ps(max) and Ps(min)) were determined over one respiratory cycle. The respiratory changes in pulse pressure (DeltaPp) were calculated as the difference between Pp(max) and Pp(min) divided by the mean of the two values and were expressed as a percentage. The respiratory changes in systolic pressure (DeltaPs) were calculated using a similar formula. The VE-induced increase in CI was >/= 15% in 16 patients (responders) and < 15% in 24 patients (nonresponders). Before VE, DeltaPp (24 +/- 9 versus 7 +/- 3%, p < 0.001) and DeltaPs (15 +/- 5 versus 6 +/- 3%, p < 0.001) were higher in responders than in nonresponders. Receiver operating characteristic (ROC) curves analysis showed that DeltaPp was a more accurate indicator of fluid responsiveness than DeltaPs. Before VE, a DeltaPp value of 13% allowed discrimination between responders and nonresponders with a sensitivity of 94% and a specificity of 96%. VE-induced changes in CI closely correlated with DeltaPp before volume expansion (r(2) = 0. 85, p < 0.001). VE decreased DeltaPp from 14 +/- 10 to 7 +/- 5% (p < 0.001) and VE-induced changes in DeltaPp correlated with VE-induced changes in CI (r(2) = 0.72, p < 0.001). It was concluded that in mechanically ventilated patients with acute circulatory failure related to sepsis, analysis of DeltaPp is a simple method for predicting and assessing the hemodynamic effects of VE, and that DeltaPp is a more reliable indicator of fluid responsiveness than DeltaPs.

          Related collections

          Author and article information

          Journal
          Am J Respir Crit Care Med
          American journal of respiratory and critical care medicine
          American Thoracic Society
          1073-449X
          1073-449X
          Jul 2000
          : 162
          : 1
          Affiliations
          [1 ] Service de Réanimation Médicale et Service de Physiologie Cardio-Respiratoire, Centre Hospitalo-Universitaire de Bicêtre, Assistance Publique-Hopitaux de Paris, Le Kremlin Bicêtre, Université Paris XI, Paris, France.
          Article
          10.1164/ajrccm.162.1.9903035
          10903232