8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Automatic Valve Plane Localization in Myocardial Perfusion SPECT/CT by Machine Learning: Anatomic and Clinical Validation

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Precise definition of the mitral valve plane (VP) during segmentation of the left ventricle for SPECT myocardial perfusion imaging (MPI) quantification often requires manual adjustment, which affects the quantification of perfusion. We developed a machine learning approach using support vector machines (SVM) for automatic VP placement. Methods: A total of 392 consecutive patients undergoing 99mTc-tetrofosmin stress (5 min; mean ± SD, 350 ± 54 MBq) and rest (5 min; 1,024 ± 153 MBq) fast SPECT MPI attenuation corrected (AC) by CT and same-day coronary CT angiography were studied; included in the 392 patients were 48 patients who underwent invasive coronary angiography and had no known coronary artery disease. The left ventricle was segmented with standard clinical software (quantitative perfusion SPECT) by 2 experts, adjusting the VP if needed. Two-class SVM models were computed from the expert placements with 10-fold cross validation to separate the patients used for training and those used for validation. SVM probability estimates were used to compute the best VP position. Automatic VP localizations on AC and non-AC images were compared with expert placement on coronary CT angiography. Stress and rest total perfusion deficits and detection of per-vessel obstructive stenosis by invasive coronary angiography were also compared. Results: Bland–Altman 95% confidence intervals (CIs) for VP localization by SVM and experts for AC stress images (bias, 1; 95% CI, −5 to 7 mm) and AC rest images (bias, 1; 95% CI, −7 to 10 mm) were narrower than interexpert 95% CIs for AC stress images (bias, 0; 95% CI, −8 to 8 mm) and AC rest images (bias, 0; 95% CI, −10 to 10 mm) ( P < 0.01). Bland–Altman 95% CIs for VP localization by SVM and experts for non-AC stress images (bias, 1; 95% CI, −4 to 6 mm) and non-AC rest images (bias, 2; 95% CI, −7 to 10 mm) were similar to interexpert 95% CIs for non-AC stress images (bias, 0; 95% CI, −6 to 5 mm) and non-AC rest images (bias, −1; 95% CI, −9 to 7 mm) ( P was not significant [NS]). For regional detection of obstructive stenosis, ischemic total perfusion deficit areas under the receiver operating characteristic curve for the 2 experts (AUC, 0.79 [95% CI, 0.7–0.87]; AUC, 0.81 [95% CI, 0.73–0.89]) and the SVM (0.82 [0.74–0.9]) for AC data were the same ( P = NS) and were higher than those for the unadjusted VP (0.63 [0.53–0.73]) ( P < 0.01). Similarly, for non-AC data, areas under the receiver operating characteristic curve for the experts (AUC, 0.77 [95% CI, 0.69–0.89]; AUC, 0.8 [95% CI, 0.72–0.88]) and the SVM (0.79 [0.71–0.87]) were the same ( P = NS) and were higher than those for the unadjusted VP (0.65 [0.56–0.75]) ( P < 0.01). Conclusion: Machine learning with SVM allows automatic and accurate VP localization, decreasing user dependence in SPECT MPI quantification.

          Related collections

          Author and article information

          Journal
          J Nucl Med
          J. Nucl. Med
          jnumed
          jnm
          Journal of Nuclear Medicine
          Society of Nuclear Medicine
          0161-5505
          1535-5667
          June 2017
          : 58
          : 6
          : 961-967
          Affiliations
          [1 ]Department of Imaging, Medicine, and Biomedical Sciences, Cedars–Sinai Medical Center, Los Angeles, California
          [2 ]Cardiac Imaging, Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland; and
          [3 ]Department of Computer Science, National Taiwan University, Taipei, Taiwan.
          Author notes
          For correspondence or reprints contact: Piotr J. Slomka, Cedars–Sinai Medical Center, 8700 Beverly Blvd., Ste. A047N, Los Angeles, CA 90048. E-mail: Piotr.Slomka@ 123456cshs.org

          Published online Nov. 3, 2016.

          Article
          PMC5450369 PMC5450369 5450369 179911
          10.2967/jnumed.116.179911
          5450369
          27811121
          3040df5b-892b-49d5-a3ae-3f6e64b1aec5
          © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
          History
          : 23 June 2016
          : 17 October 2016
          Page count
          Pages: 7
          Categories
          Cardiology
          Clinical

          myocardial perfusion imaging,SPECT quantification,machine learning,support vector classification,coronary CT angiography

          Comments

          Comment on this article