      EANM guidelines for ventilation/perfusion scintigraphy : Part 2. Algorithms and clinical considerations for diagnosis of pulmonary emboli with V/P(SPECT) and MDCT.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          As emphasized in Part 1 of these guidelines, the diagnosis of pulmonary embolism (PE) is confirmed or refuted using ventilation/perfusion scintigraphy (V/P(SCAN)) or multidetector computed tomography of the pulmonary arteries (MDCT). To reduce the costs, the risks associated with false-negative and false-positive diagnoses, and unnecessary radiation exposure, preimaging assessment of clinical probability is recommended. Diagnostic accuracy is approximately equal for MDCT and planar V/P(SCAN) and better for tomography (V/P(SPECT)). V/P(SPECT) is feasible in about 99% of patients, while MDCT is often contraindicated. As MDCT is more readily available, access to both techniques is vital for the diagnosis of PE. V/P(SPECT) gives an effective radiation dose of 1.2-2 mSv. For V/P(SPECT), the effective dose is about 35-40% and the absorbed dose to the female breast 4% of the dose from MDCT performed with a dose-saving protocol. V/P(SPECT) is recommended as a first-line procedure in patients with suspected PE. It is particularly favoured in young patients, especially females, during pregnancy, and for follow-up and research.

          Related collections

          Author and article information

          Journal
          Eur J Nucl Med Mol Imaging
          European journal of nuclear medicine and molecular imaging
          Springer Science and Business Media LLC
          1619-7089
          1619-7070
          Sep 2009
          : 36
          : 9
          Affiliations
          [1 ] Department of Clinical Physiology, Lund University Hospital, S-221 85, Lund, Sweden. Marika.bajc@med.lu.se
          Article
          10.1007/s00259-009-1169-y
          19629478
          3068a1c6-47fa-4fd4-a5b4-965d4b07eefe
          History

          Comments

          Comment on this article