      Inter- and intra–tester reliability of clinical measurement to determine medio-lateral patellar position using a pachymeter or visual assessment

      , , , , , , , , ,
      The Knee
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson's Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p=0.490) and reliability for the visual inspection (ICC=0.747) and for the pachymeter (ICC=0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC=0.604; pachymeter ICC=0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC=0.175; examiner 2 ICC=0.189; examiner 3 ICC=0.155) and pachymeter (examiner 1 ICC=0.214; examiner 2 ICC=0.246; examiner 3 ICC=0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC=[0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks' interval demonstrated an unacceptable reliability.

          Related collections

          Author and article information

          Journal
          The Knee
          The Knee
          Elsevier BV
          09680160
          January 2010
          January 2010
          : 17
          : 1
          : 92-95
          Article
          10.1016/j.knee.2009.05.008
          19574052
          30ff0690-1e71-457f-b508-eb39ccc7bf36
          © 2010

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article

          Related Documents Log