      Tear ferning in contact lens wearers.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Tear ferning (TF) has shown good sensitivity and specificity in the diagnosis of dry eye, but is a relatively uncommon test, especially in contact lens wearers. The aim of this study was to investigate the relationship between TF, ocular comfort and tear film stability amongst contact lens (CL) wearers and non-contact lens (NCL) wearers. Subjects (36 NCL, 24 CL; mean age 23.2 +/- 4.8 years) underwent assessment of non-invasive tear break up time (NIBUT), fluorescein tear break up time (FBUT) and completed the Ocular Comfort Index (OCI) questionnaire. Non-stimulated tears were collected from the inferior tear meniscus with a glass capillary. Samples of 1.5 microL were air dried, observed by light microscopy and the TF pattern quantified according to Rolando's grading scale. Significantly higher grades of TF pattern and discomfort (higher OCI scores) were observed in CL wearers compared to NCL wearers (Mann-Whitney U-test; p < 0.005 and p < 0.05 respectively). Differences in tear film stability were not significant between groups. Even when asymptomatic (low OCI scores) CL and NCL subjects were compared, TF remained significantly different (p < 0.005). In both CL and NCL subjects, TF displayed poor correlation with tear film stability tests and OCI scores. Higher TF grades in CL wearers, even if asymptomatic, indicate an unfavourable ratio of salt to macromolecule concentration within the tear film of such subjects. The lack of significant difference in TF between symptomatic CL and NCL wearers could suggest similar aetiology (tear film hyperosmolarity) in each cohort. The TF technique demonstrates limited sensitivity and specificity for the prediction of ocular surface comfort in both CL and NCL wearers.

          Related collections

          Author and article information

          Journal
          Ophthalmic Physiol Opt
          Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
          Wiley
          1475-1313
          0275-5408
          Mar 2009
          : 29
          : 2
          Affiliations
          [1 ] Contact Lens and Anterior Eye Research (CLAER) Unit, School of Optometry and Vision Sciences, Cardiff University, Maindy Road, Cardiff, UK.
          Article
          OPO626
          10.1111/j.1475-1313.2008.00626.x
          19236590
          31405519-a66e-451c-904e-c2b78dbd1465
          History

          Comments

          Comment on this article