16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Utility of transesophageal echocardiography for transcatheter occlusion of patent ductus arteriosus in dogs: influence on the decision-making process.

      Journal of Veterinary Internal Medicine
      Animals, Cardiac Catheterization, methods, veterinary, Decision Making, Dog Diseases, surgery, Dogs, Ductus Arteriosus, Patent, Echocardiography, Transesophageal, Female, Male

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Appropriate device selection for transcatheter occlusion of patent ductus arteriosus (PDA) is essential to procedural success. To determine if transesophageal echocardiography (TEE) influences device selection for PDA occlusion and to report benefits, limitations, and complications associated with TEE. Twenty-two client-owned dogs with left-to-right shunting PDA. PDA dimensions were obtained via transthoracic echocardiography (TTE) and then TEE followed by angiography. Based solely on information from TTE and angiography, an initial device type and size were selected. After initial device selection, TEE measurements were disclosed and changes in device selection were recorded. After device release, angiography, TEE, or both were performed to assess occlusion. An Amplatz canine duct occluder (ACDO) was securely positioned and released in 21 dogs and an embolization coil was deployed in 1 dog. Based on TEE evaluation, initial selected device type was unchanged but ACDO size was changed in 3 dogs. TEE was utilized throughout the procedure allowing real time visualization of device deployment, release and assessment of closure in 17 dogs. No complications occurred related to TEE. Complete PDA closure was achieved in all dogs. TEE provided anatomic information regarding PDA morphology that closely approximated angiographic ductal dimensions while aiding in device deployment, release and confirmation of closure. We conclude that TEE provides complementary anatomical and intraprocedural information and is well tolerated in dogs. Copyright © 2010 by the American College of Veterinary Internal Medicine.

          Related collections

          Author and article information

          Journal
          20738766
          10.1111/j.1939-1676.2010.0587.x

          Chemistry
          Animals,Cardiac Catheterization,methods,veterinary,Decision Making,Dog Diseases,surgery,Dogs,Ductus Arteriosus, Patent,Echocardiography, Transesophageal,Female,Male

          Comments

          Comment on this article