5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Bioelectrical Impedance Analysis (BIA) detects body resistance increase in dogs undergoing blood donation

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Using raw parameters of bioelectrical impedance analysis (BIA) and derived Phase Angle (PhA) has emerged as an alternative to conventional predictive BIA for body fluid volumes and body composition estimation in human patients, offering an approach independent of predictive equations. Classic predictive equation-based BIA remains unsuitable for veterinary clinical practice due to the high morphological variability within the canine species. This study aimed to validate the feasibility of BIA in dogs and assess its utility in detecting changes in body fluid volumes, particularly in blood donation. Sixty healthy blood donor dogs and ten controls were longitudinally assessed using BIA raw parameters with a portable analyzer at a 50 kHz frequency. Measurements were performed before and after blood donation in donor dogs, whereas in controls, they were carried out at two time points, approximating the timing of a donation. Significant increases in raw bioelectrical parameters were observed after blood donation in the donor group, while differences were not statistically significant in controls. Hematocrit values did not significantly differ between the two time points in both groups. These findings suggest the feasibility of using BIA to detect changes in body fluid volumes in dogs undergoing blood donation, highlighting its potential application in veterinary medicine. Further research should explore the applicability of BIA in spontaneous pathological conditions involving fluid loss or retention and investigate the potential utility of PhA as a prognostic or monitoring tool in veterinary clinical practice. This study provides valuable insights into using BIA in canine medicine, paving the way for enhanced diagnostic and monitoring strategies in clinical practice.

          Supplementary Information

          The online version contains supplementary material available at 10.1007/s11259-024-10555-1.

          Related collections

          Most cited references39

          • Record: found
          • Abstract: not found
          • Article: not found

          2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Bioelectrical impedance analysis--part I: review of principles and methods.

            U KYLE (2004)
            The use of bioelectrical impedance analysis (BIA) is widespread both in healthy subjects and patients, but suffers from a lack of standardized method and quality control procedures. BIA allows the determination of the fat-free mass (FFM) and total body water (TBW) in subjects without significant fluid and electrolyte abnormalities, when using appropriate population, age or pathology-specific BIA equations and established procedures. Published BIA equations validated against a reference method in a sufficiently large number of subjects are presented and ranked according to the standard error of the estimate. The determination of changes in body cell mass (BCM), extra cellular (ECW) and intra cellular water (ICW) requires further research using a valid model that guarantees that ECW changes do not corrupt the ICW. The use of segmental-BIA, multifrequency BIA, or bioelectrical spectroscopy in altered hydration states also requires further research. ESPEN guidelines for the clinical use of BIA measurements are described in a paper to appear soon in Clinical Nutrition.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Bioelectrical phase angle and impedance vector analysis--clinical relevance and applicability of impedance parameters.

              The use of phase angle (PhA) and raw parameters of bioelectrical impedance analysis (BIA) has gained attention as alternative to conventional error-prone calculation of body composition in disease. This review investigates the clinical relevance and applicability of PhA and Bioelectrical Impedance Vector Analysis (BIVA) which uses the plot of resistance and reactance normalized per height. A comprehensive literature search was conducted using Medline identifying studies relevant to this review until March 2011. We included studies on the use of PhA or BIVA derived from tetrapolar BIA in out- and in-patient settings or institutionalized elderly. Numerous studies have proven the prognostic impact of PhA regarding mortality or postoperative complications in different clinical settings. BIVA has been shown to provide information about hydration and body cell mass and therefore allows assessment of patients in whom calculation of body composition fails due to altered hydration. Reference values exist for PhA and BIVA facilitating interpretation of data. PhA, a superior prognostic marker, should be considered as a screening tool for the identification of risk patients with impaired nutritional and functional status, BIVA is recommended for further nutritional assessment and monitoring, in particular when calculation of body composition is not feasible. Copyright © 2012 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
                Bookmark

                Author and article information

                Contributors
                arianna.miglio@unipg.it
                Journal
                Vet Res Commun
                Vet Res Commun
                Veterinary Research Communications
                Springer Netherlands (Dordrecht )
                0165-7380
                1573-7446
                27 September 2024
                27 September 2024
                2024
                : 48
                : 6
                : 3889-3897
                Affiliations
                [1 ]Department of Veterinary Medicine, University of Perugia, ( https://ror.org/00x27da85) Perugia, Italy
                [2 ]Department of Veterinary Medicine, University of Sassari, ( https://ror.org/01bnjbv91) Sassari, Italy
                Author information
                http://orcid.org/0000-0002-5459-6298
                Article
                10555
                10.1007/s11259-024-10555-1
                11538226
                39331344
                33ca7e3b-8b51-4519-a2f5-678d34f63619
                © The Author(s) 2024

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 20 May 2024
                : 20 September 2024
                Funding
                Funded by: Università degli Studi di Perugia
                Categories
                Research
                Custom metadata
                © Springer Nature B.V. 2024

                Veterinary medicine
                bioelectrical impedance analysis,dog,phase angle,blood donation,total body water

                Comments