          Abstract

          This work presents a simple and fast method for colchicine (CO) determination in pharmaceutical formulations and urine by multiple pulse amperometry (MPA) with flow injection analysis (FIA) system using a boron-doped diamond electrode. In optimized conditions, it was possible to quantify CO in urine samples without interference of uric acid and ascorbic acid. The working linear range for CO quantification was achieved from 1.0 × 10-7 to 0.5 × 10-3mol L-1 with a low limit of detection of 2.14 × 10-8mol L-1. Furthermore, the proposed method showed high repeatability for 10 consecutive injections of 1.0 × 10-4mol L-1 CO (relative standard deviation = 1.28%) and good analytical frequency (30 determinations per hour). The addition and recovery studies in all pharmaceutical samples were approximately 100% and the results for CO determination were compared by high performance liquid chromatography (HPLC) with UV detection.

          Related collections

          Author and article information

          Contributors
          Role: ND
          Role: ND
          Role: ND
          Role: ND
          Role: ND
          Role: ND
          Role: ND
          Role: ND
          Role: ND
          Journal
          jbchs
          Journal of the Brazilian Chemical Society
          J. Braz. Chem. Soc.
          Sociedade Brasileira de Química (São Paulo, SP, Brazil )
          0103-5053
          1678-4790
          September 2018
          : 29
          : 9
          : 1796-1802
          Affiliations
          [6] Diamantina Minas Gerais orgnameUniversidade Federal dos Vales do Jequitinhonha e Mucuri orgdiv1Departamento de Farmácia Brazil
          [1] São João Del Minas Gerais orgnameUniversidade Federal de São João del-Rei orgdiv1Departamento de Ciências Naturais Brazil
          [2] Diamantina Minas Gerais orgnameUniversidade Federal dos Vales do Jequitinhonha e Mucuri orgdiv1Departamento de Química Brazil
          [4] São Luís orgnameUniversidade Federal do Maranhão orgdiv1Departamento de Química Brazil
          [5] Monte Carmelo Minas Gerais orgnameUniversidade Federal de Uberlândia orgdiv1Instituto de Química Brazil
          [3] Betim Minas Gerais orgnameInstituto Federal de Minas Gerais Brazil
          Article
          S0103-50532018000901796
          10.21577/0103-5053.20180055
          33f969f0-00c4-4493-a73e-c4ec2bcdd435

          This work is licensed under a Creative Commons Attribution 4.0 International License.

          History
          : 20 March 2018
          : 10 January 2018
          Page count
          Figures: 0, Tables: 0, Equations: 0, References: 51, Pages: 7
          Product

          SciELO Brazil


          flow-injection analysis,colchicine,boron-doped diamond,multiple pulse amperometry

          Comments

          Comment on this article

          Related Documents Log