6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Word Recognition Variability With Cochlear Implants : “Perceptual Attention” Versus “Auditory Sensitivity”

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Cochlear implantation does not automatically result in robust spoken language understanding for postlingually deafened adults. Enormous outcome variability exists, related to the complexity of understanding spoken language through cochlear implants (CIs), which deliver degraded speech representations. This investigation examined variability in word recognition as explained by "perceptual attention" and "auditory sensitivity" to acoustic cues underlying speech perception.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: found
          • Article: not found

          Factors affecting open-set word recognition in adults with cochlear implants.

          A great deal of variability exists in the speech-recognition abilities of postlingually deaf adult cochlear implant (CI) recipients. A number of previous studies have shown that duration of deafness is a primary factor affecting CI outcomes; however, there is little agreement regarding other factors that may affect performance. The objective of the present study was to determine the source of variability in CI outcomes by examining three main factors, biographic/audiologic information, electrode position within the cochlea, and cognitive abilities in a group of newly implanted CI recipients. Participants were 114 postlingually deaf adults with either the Cochlear or Advanced Bionics CI systems. Biographic/audiologic information, aided sentence-recognition scores, a high resolution temporal bone CT scan and cognitive measures were obtained before implantation. Monosyllabic word recognition scores were obtained during numerous test intervals from 2 weeks to 2 years after initial activation of the CI. Electrode position within the cochlea was determined by three-dimensional reconstruction of pre- and postimplant CT scans. Participants' word scores over 2 years were fit with a logistic curve to predict word score as a function of time and to highlight 4-word recognition metrics (CNC initial score, CNC final score, rise time to 90% of CNC final score, and CNC difference score). Participants were divided into six outcome groups based on the percentile ranking of their CNC final score, that is, participants in the bottom 10% were in group 1; those in the top 10% were in group 6. Across outcome groups, significant relationships from low to high performance were identified. Biographic/audiologic factors of age at implantation, duration of hearing loss, duration of hearing aid use, and duration of severe-to-profound hearing loss were significantly and inversely related to performance as were frequency modulated tone, sound-field threshold levels obtained with the CI. That is, the higher-performing outcome groups were younger in age at the time of implantation, had shorter duration of severe-to-profound hearing loss, and had lower CI sound-field threshold levels. Significant inverse relationships across outcome groups were also observed for electrode position, specifically the percentage of electrodes in scala vestibuli as opposed to scala tympani and depth of insertion of the electrode array. In addition, positioning of electrode arrays closer to the modiolar wall was positively correlated with outcome. Cognitive ability was significantly and positively related to outcome; however, age at implantation and cognition were highly correlated. After controlling for age, cognition was no longer a factor affecting outcomes. There are a number of factors that limit CI outcomes. They can act singularly or collectively to restrict an individual's performance and to varying degrees. The highest performing CI recipients are those with the least number of limiting factors. Knowledge of when and how these factors affect performance can favorably influence counseling, device fitting, and rehabilitation for individual patients and can contribute to improved device design and application.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants.

            Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear implant. Recognition was measured as a function of the number of spectral channels (noise bands or electrodes) at signal-to-noise ratios of + 15, + 10, +5, 0 dB, and in quiet. Performance with three different speech processing strategies (SPEAK, CIS, and SAS) was similar across all conditions, and improved as the number of electrodes increased (up to seven or eight) for all conditions. For all noise levels, vowel and consonant recognition with the SPEAK speech processor did not improve with more than seven electrodes, while for normal-hearing listeners, performance continued to increase up to at least 20 channels. Speech recognition on more difficult speech materials (word and sentence recognition) showed a marginally significant increase in Nucleus-22 listeners from seven to ten electrodes. The average implant score on all processing strategies was poorer than scores of NH listeners with similar processing. However, the best CI scores were similar to the normal-hearing scores for that condition (up to seven channels). CI listeners with the highest performance level increased in performance as the number of electrodes increased up to seven, while CI listeners with low levels of speech recognition did not increase in performance as the number of electrodes was increased beyond four. These results quantify the effect of number of spectral channels on speech recognition in noise and demonstrate that most CI subjects are not able to fully utilize the spectral information provided by the number of electrodes used in their implant.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Pre-, Per- and Postoperative Factors Affecting Performance of Postlinguistically Deaf Adults Using Cochlear Implants: A New Conceptual Model over Time

              Objective To test the influence of multiple factors on cochlear implant (CI) speech performance in quiet and in noise for postlinguistically deaf adults, and to design a model of predicted auditory performance with a CI as a function of the significant factors. Study Design Retrospective multi-centre study. Methods Data from 2251 patients implanted since 2003 in 15 international centres were collected. Speech scores in quiet and in noise were converted into percentile ranks to remove differences between centres. The influence of 15 pre-, per- and postoperative factors, such as the duration of moderate hearing loss (mHL), the surgical approach (cochleostomy or round window approach), the angle of insertion, the percentage of active electrodes, and the brand of device were tested. The usual factors, duration of profound HL (pHL), age, etiology, duration of CI experience, that are already known to have an influence, were included in the statistical analyses. Results The significant factors were: the pure tone average threshold of the better ear, the brand of device, the percentage of active electrodes, the use of hearing aids (HAs) during the period of pHL, and the duration of mHL. Conclusions A new model was designed showing a decrease of performance that started during the period of mHL, and became faster during the period of pHL. The use of bilateral HAs slowed down the related central reorganization that is the likely cause of the decreased performance.
                Bookmark

                Author and article information

                Journal
                Ear and Hearing
                Ear and Hearing
                Ovid Technologies (Wolters Kluwer Health)
                0196-0202
                2016
                2016
                : 37
                : 1
                : 14-26
                Article
                10.1097/AUD.0000000000000204
                4684470
                26301844
                34d44ad7-9f60-4a8d-9f09-2a1ffc51d4e0
                © 2016
                History

                Comments

                Comment on this article