222
views
0
recommends
+1 Recommend
1 collections
    8
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Immunoassays for Affinity, Avidity and Competition: Methods to Evaluate Monoclonal and Polyclonal Antibodies Useful Assays in Development of New Antibodies, Better Understanding of Commercial Antibodies: Their Usefulness in Specific Aims of Research

      1
      International Journal of Translational Science
      River Publishers

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Most cited references3

          • Record: found
          • Abstract: not found
          • Article: not found

          Enzyme-linked immunosorbent assay (ELISA). Quantitative assay of immunoglobulin G.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA).

            This brief note addresses the historical background of the invention of the enzyme immunoassay (EIA) and enzyme-linked immunosorbent assay (ELISA). These assays were developed independently and simultaneously by the research group of Peter Perlmann and Eva Engvall at Stockholm University in Sweden and by the research group of Anton Schuurs and Bauke van Weemen in The Netherlands. Today, fully automated instruments in medical laboratories around the world use the immunoassay principle with an enzyme as the reporter label for routine measurements of innumerable analytes in patient samples. The impact of EIA/ELISA is reflected in the overwhelmingly large number of times it has appeared as a keyword in the literature since the 1970s. Clinicians and their patients, medical laboratories, in vitro diagnostics manufacturers, and worldwide healthcare systems owe much to these four inventors.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              A simple set of validation steps identifies and removes false results in a sandwich enzyme-linked immunosorbent assay caused by anti-animal IgG antibodies in plasma from arthritis patients

              Rheumatoid arthritis (RA) and spondyloarthritis (SpA) are chronic diseases characterized by activation of the immune system and production of antibodies. Thus, rheumatoid factor, anti-animal IgG antibodies and heterophilic antibodies in plasma samples from arthritis patients can interfere with immunoassays such as sandwich enzyme-linked immunosorbent assay (ELISA) systems often used in arthritis research. However, standard methodologies on how to test for false results caused by these antibodies are lacking. The objective of this study was to design a simple set of steps to validate a sandwich ELISA before using it for measuring analytes in plasma from arthritis patients. An interleukin-24 (IL-24) sandwich ELISA system was prepared with a monoclonal mouse capture antibody and a polyclonal goat detection antibody and tested for interference by rheumatoid factor, anti-animal IgG antibodies and heterophilic antibodies. Plasma samples from 23 patients with RA and SpA were used. No differences were found between plasma samples measured in wells coated with anti-IL-24 specific antibody and in wells coated with isotype control antibody (false positive results), and recombinant human IL-24 was not recovered in spiked samples (false negative results). This interference was removed after preincubating the plasma samples from patients with arthritis with goat or bovine IgG, suggesting that anti-animal IgG antibodies found in the plasma of the arthritis patients caused the false results. Additional testing showed that the signal-to-noise ratio could be increased by titration of the capture and detection antibodies and by using the ELAST amplification system. Finally, the calculated concentration of IL-24 was increased in ethylenediaminetetraacetic acid (EDTA) plasma compared to heparin plasma and serum and decreased with repetitive freeze/thaw cycles of the samples illustrating how sample handling could additionally contribute to the variations reported by different laboratories in measurement of the same analyte. This study proposes a simple set of validation steps to evaluate and optimize a sandwich ELISA before using it for measuring analytes in plasma from arthritis patients. Anti-animal IgG antibodies are also present in healthy individuals, suggesting that validation of ELISA systems for measuring non-arthritis samples could also be improved by this simple set of validation steps.
                Bookmark

                Author and article information

                Journal
                JTS
                International Journal of Translational Science
                IJTS
                River Publishers
                2246-8765
                2016
                : 2016
                : 1
                : 131-134
                Affiliations
                [1 ]New Jersey Medical School/Rutgers University/Newark NJ, USA
                Article
                10.13052/ijts2246-8765.2016.001
                3667a902-d2a6-4ce5-8f71-e9a77b859f31
                © 2016

                This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

                History

                Engineering,Materials science
                Engineering, Materials science

                Comments

                Comment on this article