      Three distinct directions of intramural activation reveal nonuniform side-to-side electrical coupling of ventricular myocytes.

      Circulation. Arrhythmia and Electrophysiology
      Action Potentials, physiology, Animals, Anisotropy, Cardiac Pacing, Artificial, Computer Simulation, Electric Conductivity, Heart, Heart Ventricles, cytology, Models, Cardiovascular, Myocardium, Myocytes, Cardiac, Swine, Tachycardia, Ventricular, physiopathology

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The anisotropy of cardiac tissue is a key determinant of 3D electric propagation and the stability of activation wave fronts in the heart. The electric properties of ventricular myocardium are widely assumed to be axially anisotropic, with activation propagating most rapidly in the myofiber direction and at uniform velocity transverse to this. We present new experimental evidence that contradicts this view. For the first time, high-density intramural electric mapping (325 electrodes at approximately 4x4x1-mm spacing) from pig left ventricular tissue was used to reconstruct 3D paced activation surfaces projected directly onto 3D tissue structure imaged throughout the same left ventricular volume. These data from 5 hearts demonstrate that ventricular tissue is electrically orthotropic with 3 distinct propagation directions that coincide with local microstructural axes defined by the laminar arrangement of ventricular myocytes. The maximum conduction velocity of 0.67+/-0.019 ms(-1) was aligned with the myofiber axis. However, transverse to this, the maximum conduction velocity was 0.30+/-0.010 ms(-1), parallel to the myocyte layers and 0.17+/-0.004 ms(-1) normal to them. These orthotropic conduction velocities give rise to preferential activation pathways across the left ventricular free wall that are not captured by structurally detailed computer models, which incorporate axially anisotropic electric properties. Our findings suggest that current views on uniform side-to-side electric coupling in the heart need to be revised. In particular, nonuniform laminar myocardial architecture and associated electric orthotropy should be included in future models of initiation and maintenance of ventricular arrhythmia.

          Related collections

          Author and article information

          Comments

          Comment on this article

          Related Documents Log