      Cutting errors in preparation of femoral components in total knee arthroplasty

      , ,
      The Journal of Arthroplasty
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Cutting errors that occur during preparation of the femoral component can deter fixation in cementless total knee arthroplasty. This study evaluated the causes of femoral cutting errors and identified methods to minimize these errors. The cutting error caused by toggle of the saw blade in the guide-slot was measured with wood blocks, a cutting guide with 1.5 mm guide slots, and four kinds of saw blades (narrow and wide blades with thicknesses of standard 1.2 mm and thicker 1.4 mm). Another cause of cutting errors, relative motions between the cutting guide and distal femur due to vibration of the saw blade during bone cuts, was measured with preserved cadaver femurs. Various combined fixation methods with intramedullary rod, pins, and clamps were compared. The maximum cutting error caused by toggle of the saw blade in the slot was significantly reduced by using the thicker 1.4 mm saw blade, but the differences between wide and narrow blades in each thickness were not significant. Mean maximum cutting error at the cutting depth of 5 cm with 1.2 mm thick saw blades was 802 microns, and with 1.4 mm thick saw blades it was 488 microns. In the measurement of relative motion, fixation with only pins or clamps did not provide tight fixation and had deflections from 200 microns to more than 1 mm. The best fixation was obtained by combining fixation methods of intramedullary rod and pins or clamps. This resulted in total movement of less than 100 microns. The results of this study indicate that both toggle of the saw blade in the slot and motion of the cutting guide can cause major cutting errors. Cutting error can be minimized by using thicker saw blades and by fixing the cutting guide to the distal femur with combined fixation methods of a central rod and peripheral pins or clamps.

          Related collections

          Author and article information

          Journal
          The Journal of Arthroplasty
          The Journal of Arthroplasty
          Elsevier BV
          08835403
          October 1993
          October 1993
          : 8
          : 5
          : 503-510
          Article
          10.1016/S0883-5403(06)80215-9
          8245995
          390e4f8c-dc5c-4fe0-be50-4621dc0d88bd
          © 1993

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article