      Multicenter Evaluation of the Vitek MS v3.0 System for the Identification of Filamentous Fungi

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          ABSTRACT

          Invasive fungal infections are an important cause of morbidity and mortality affecting primarily immunocompromised patients. While fungal identification to the species level is critical to providing appropriate therapy, it can be slow and laborious and often relies on subjective morphological criteria. The use of matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry has the potential to speed up and improve the accuracy of identification. In this multicenter study, we evaluated the accuracy of the Vitek MS v3.0 system in identifying 1,601 clinical mold isolates compared to identification by DNA sequence analysis and supported by morphological and phenotypic testing. Among the 1,519 isolates representing organisms in the v3.0 database, 91% ( n = 1,387) were correctly identified to the species level. An additional 27 isolates (2%) were correctly identified to the genus level. Fifteen isolates were incorrectly identified, due to either a single incorrect identification ( n = 13) or multiple identifications from different genera ( n = 2). In those cases, when a single identification was provided that was not correct, the misidentification was within the same genus. The Vitek MS v3.0 was unable to identify 91 (6%) isolates, despite repeat testing. These isolates were distributed among all the genera. When considering all isolates tested, even those that were not represented in the database, the Vitek MS v3.0 provided a single correct identification 98% of the time. These findings demonstrate that the Vitek MS v3.0 system is highly accurate for the identification of common molds encountered in the clinical mycology laboratory.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: found
          • Article: not found

          Development of a clinically comprehensive database and a simple procedure for identification of molds from solid media by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

          Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a powerful tool for the rapid and highly accurate identification of clinical pathogens but has not been utilized extensively in clinical mycology due to challenges in developing an effective protein extraction method and the limited databases available. Here, we developed an alternate extraction procedure and constructed a highly stringent database comprising 294 individual isolates representing 76 genera and 152 species. To our knowledge, this is the most comprehensive clinically relevant mold database developed to date. When challenged with 421 blinded clinical isolates from our institution, by use of the BioTyper software, accurate species-level (score of ≥ 2.0) and genus-level (score of ≥ 1.7) identifications were obtained for 370 (88.9%) and 18 (4.3%) isolates, respectively. No isolates were misidentified. Of the 33 isolates (7.8%) for which there was no identification (score of <1.7), 25 were basidiomycetes not associated with clinical disease and 8 were Penicillium species that were not represented in the database. Our library clearly outperformed the manufacturer's database that was obtained with the instrument, which identified only 3 (0.7%) and 26 (6.2%) isolates at species and genus levels, respectively. Identification was not affected by different culture conditions. Implementation into our routine workflow has revolutionized our mycology laboratory efficiency, with improved accuracy and decreased time for mold identification, eliminating reliance on traditional phenotypic features.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Species identification of Aspergillus, Fusarium and Mucorales with direct surface analysis by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

            Accurate species discrimination of filamentous fungi is essential, because some species have specific antifungal susceptibility patterns, and misidentification may result in inappropriate therapy. We evaluated matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for species identification through direct surface analysis of the fungal culture. By use of culture collection strains representing 55 species of Aspergillus, Fusarium and Mucorales, a reference database was established for MALDI-TOF MS-based species identification according to the manufacturer's recommendations for microflex measurements and MALDI BioTyper 2.0 software. The profiles of young and mature colonies were analysed for each of the reference strains, and species-specific spectral fingerprints were obtained. To evaluate the database, 103 blind-coded fungal isolates collected in the routine clinical microbiology laboratory were tested. As a reference method for species designation, multilocus sequencing was used. Eighty-five isolates were unequivocally identified to the species level (≥99% sequence similarity); 18 isolates producing ambiguous results at this threshold were initially rated as identified to the genus level only. Further molecular analysis definitively assigned these isolates to the species Aspergillus oryzae (17 isolates) and Aspergillus flavus (one isolate), concordant with the MALDI-TOF MS results. Excluding nine isolates that belong to the fungal species not included in our reference database, 91 (96.8%) of 94 isolates were identified by MALDI-TOF MS to the species level, in agreement with the results of the reference method; three isolates were identified to the genus level. In conclusion, MALDI-TOF MS is suitable for the routine identification of filamentous fungi in a medical microbiology laboratory. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Molecular and phenotypic data supporting distinct species statuses for Scedosporium apiospermum and Pseudallescheria boydii and the proposed new species Scedosporium dehoogii.

              Based on the morphological, physiologic, and molecular (beta-tubulin gene) study of 141 isolates of the Pseudallescheria boydii species complex (including several synonyms) and relatives, the new species Scedosporium dehoogii is proposed. Scedosporium apiospermum and P. boydii are considered two different species and the new name Scedosporium boydii is proposed for the anamorph of the latter species. A summary of the key morphological and physiological features for distinguishing the species of Pseudallescheria/Scedosporium is provided.
                Bookmark

                Author and article information

                Journal
                Journal of Clinical Microbiology
                J Clin Microbiol
                American Society for Microbiology
                0095-1137
                1098-660X
                February 2018
                January 24 2018
                November 15 2017
                : 56
                : 2
                : e01353-17
                Article
                10.1128/JCM.01353-17
                5786734
                29142047
                3a925d10-a426-432f-8aa4-10578acb7685
                © 2017
                History

                Comments

                Comment on this article