14
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Pentoxifylline reduces lung allograft reperfusion injury.

      The Annals of thoracic surgery
      Animals, Dogs, Hypertonic Solutions, Lung, enzymology, Lung Transplantation, physiology, Organ Preservation, Pentoxifylline, therapeutic use, Peroxidase, metabolism, Pulmonary Circulation, Pulmonary Gas Exchange, drug effects, Reperfusion Injury, prevention & control, Time Factors

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Early graft dysfunction remains a significant problem in clinical lung transplantation. Pentoxifylline, a methylxanthine derivative, has been shown to have various beneficial effects on neutrophil-induced lung injury. We investigated effects of pentoxifylline on early posttransplantation lung function in a canine allograft model. Ten dogs underwent left lung allotransplantation. Donor lungs were flushed with modified Euro-Collins solution (50 mL/kg) and stored in an inflated state for 18 hours at 1 degrees C. In five experiments (group I), pentoxifylline was added to the flush and storage solutions (200 mg/L) at the time of harvest. The recipient animals received pentoxifylline (20 mg/kg intravenously) before reperfusion followed by pentoxifylline (0.1 mg.kg-1.min-1 intravenously) during the 6-hour posttransplantation assessment period. In group II, donors and recipients received no pentoxifylline. To evaluate only allograft function, the right main pulmonary artery and bronchus were ligated immediately after implantation. For 6 hours thereafter hemodynamics and gas exchange were assessed at 15-minute intervals while the animal was ventilated at an inspired oxygen fraction of 1.0. After 1 hour of assessment there was a significant difference in gas exchange between the groups, which persisted until the end of the study. By the end of the 6-hour assessment, the mean arterial oxygen tension was 236.7 mm Hg for group I versus 101.1 mm Hg for group II (p < 0.01), and the alveolar-arterial oxygen difference was 443.1 mm Hg versus 562.2 mm Hg (p < 0.015). Hemodynamics were not different between groups.(ABSTRACT TRUNCATED AT 250 WORDS)

          Related collections

          Author and article information

          Comments

          Comment on this article