12
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Predictors and Outcomes of Vitrectomy and Silicone Oil Injection in Advanced Diabetic Retinopathy

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          To evaluate visual and anatomical results and identify factors that influence vitrectomy and silicone oil (SO) injection outcomes in proliferative diabetic retinopathy (PDR).

          Methods

          This retrospective study included 236 eyes with PDR that were undergoing vitrectomy and SO injection with >3-month follow-up. The primary outcomes were final best-corrected visual acuity (BCVA) and retinal attachment rate.

          Results

          At the final visit (mean, 88 ± 58 weeks), complete, partial, and no retinal attachment were observed in 86.9%, 10.6%, and 2.5% of patients, respectively. A total of 155 eyes had experienced SO removal, while 81 had SO in place. The mean initial BCVA was 1.9 ± 0.7 logarithm of the minimum angle of resolution (logMAR) and significantly improved to 1.7 ± 0.8 logMAR ( p = 0.001). Initial macular detachment (adjusted odds ratio [AOR], 0.25), development of iatrogenic break (AOR, 0.25), and use of heavy SO (AOR, 0.13) were independently associated with a lower risk of final retinal attachment, and SO removal was associated with a higher incidence (AOR, 7.55). Better baseline BCVA was associated with a higher risk of final BCVA ≥20 / 200.

          Conclusions

          Despite an encouraging outcome based on anatomical data in advanced PDR treated with vitrectomy and SO, the functional prognosis was not satisfying for patients. Eyes with better vision at baseline had a more favorable prognosis, whereas eyes with initial macular detachment, intraoperative iatrogenic break, or heavy SO showed more unfavorable outcomes. In selected cases, extending the time of SO use did not worsen the prognosis.

          Related collections

          Most cited references34

          • Record: found
          • Abstract: found
          • Article: not found

          Lens opacities classification system II (LOCS II)

          The Lens Opacities Classification System, version II (LOCS II), uses a set of colored slit-lamp and retroillumination transparencies to grade different degrees of nuclear, cortical, and subcapsular cataract. The system uses four nuclear standards for grading nuclear opalescence and color, five cortical standards, and four subcapsular standards. The LOCS II can be used to grade patients' cataracts at the slit lamp or to grade slit-lamp and retroillumination photographs; it is easy to learn and can be applied consistently by different observers. We obtained very good interobserver reproducibility of the clinical gradings at the slit lamp, excellent intraobserver reproducibility, very good to excellent interobserver reproducibility of photographic gradings, and good agreement between clinical and photographic gradings. The LOCS II is potentially useful for both cross-sectional and longitudinal studies of cataract.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            The use of liquid silicone in retinal detachment surgery.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Silicone oil in the repair of complex retinal detachments. A prospective observational multicenter study.

              This study aimed to report anatomic and visual acuity outcomes and complications after 1000-centistoke silicone oil was used as a retinal tamponade for the treatment of complex retinal detachments. Prospective observational multicenter study conducted at community and university-based ophthalmology clinics. The study cohort consisted of 2439 patients (2573 eyes) treated for complex retinal detachments associated with cytomegalovirus (CMV) necrotizing retinitis or a non-CMV etiology, including proliferative diabetic retinopathy, giant retinal tears, proliferative vitreoretinopathy, or ocular trauma. Vitrectomy surgery was performed for complex retinal detachment with 1000-centistoke silicone oil as the retinal tamponade. Anatomic outcomes were complete retinal attachment and macular attachment. Visual acuity outcomes were ambulatory vision (> or = 4/200) and preservation of preoperative visual acuity. Complications were rates of secondary intraocular pressure elevation (> or = 30 mmHg), hypotony (< or = 5 mmHg), corneal opacification (including band keratopathy, corneal edema, and corneal abrasions), oil emulsification, and cataract. Outcomes were assessed 6, 12, and 24 months after surgery. At the 6-month examination, the retina was completely attached in 178 (78%) of 228 CMV eyes and in 855 (70%) of 1219 non-CMV eyes. The macula was attached in 216 (95%) of 228 and 1062 (89%) of 1189 CMV and non-CMV eyes, respectively. Ambulatory vision was noted in 151 (65%) of 234 CMV eyes and in 480 (38%) of 1251 non-CMV eyes. Visual acuity was preserved in 106 (46%) of 230 and 1035 (84%) of 1229 CMV and non-CMV eyes, respectively. The corresponding rates of complications for CMV and non-CMV eyes were: elevated intraocular pressure, 0 (0%) of 196 and 35 (3%) of 1196; hypotony, 11 (6%) of 196 and 228 (19%) of 1196; corneal opacity, 13 (6%) of 229 and 326 (26%) of 1248; emulsification, 3 (1%) of 211 and 29 (3%) of 959; and cataract in phakic eyes, 118 (64%) of 185 and 50 (63%) of 80. Retinal reattachment was achieved in the majority of eyes using vitrectomy and silicone oil retinal tamponade. Complication rates generally were less frequent in CMV eyes, but follow-up was shorter in this group of patients, largely because of reduced life expectancy. Cataract frequently developed in phakic eyes of study patients. Use of 1000-centistoke silicone oil can be considered in the management of complex retinal detachments associated with multiple etiologies.
                Bookmark

                Author and article information

                Journal
                Korean J Ophthalmol
                Korean J Ophthalmol
                KJO
                Korean Journal of Ophthalmology : KJO
                The Korean Ophthalmological Society
                1011-8942
                2092-9382
                June 2017
                12 May 2017
                : 31
                : 3
                : 217-229
                Affiliations
                [1 ]Ophthalmic Epidemiology Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
                [2 ]Ophthalmic Research Center, Labbafinejad and Imam Hossein Medical Centers, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
                [3 ]Department of Ophthalmology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
                [4 ]Department of Epidemiology and Biostatistics, Tehran University of Medical Sciences, Tehran, Iran.
                Author notes
                Corresponding Author: Alireza Ramezani, MD. Ophthalmic Epidemiology Research Center, No. 23, Boostan 9 St., Pasdaran Ave., Tehran 16666, Iran. Tel: 98-21-22585952, Fax: 98-21-22562138, arramezani@ 123456gmail.com
                Article
                10.3341/kjo.2016.0018
                5469925
                28534343
                3e349326-36bf-47ae-8696-e6eb447fddd7
                © 2017 The Korean Ophthalmological Society

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 29 February 2016
                : 21 March 2016
                Categories
                Original Article

                Ophthalmology & Optometry
                diabetic retinopathy,outcome,silicone oils,vitrectomy
                Ophthalmology & Optometry
                diabetic retinopathy, outcome, silicone oils, vitrectomy

                Comments

                Comment on this article