40
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Indications for 3-D diagnostics and navigation in dental implantology with the focus on radiation exposure: a systematic review

      review-article

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Dental implants are a common restorative method used to replace missing teeth. Implant placement techniques guided by three-dimensional imaging and navigation are becoming more widely available.

          Objective

          The present review focused on the following questions: 1. What are the advantages and disadvantages of 2-D versus 3-D imaging in dental implantology? 2. What are the advantages and disadvantages of freehand implant placement in comparison with navigation-guided implant placement?

          Methods

          A systematic review was performed, based on the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement. The following libraries were searched for relevant literature: PubMed, Embase, Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften (AWMF) Online, and the Cochrane Library. The risk of bias was assessed using the Scottish Intercollegiate Guidelines Network (SiGN) checklist. A total of 70 studies were included after screening, and the evidence from these was gathered for review.

          Results

          Three-dimensional imaging is advantageous in terms of image quality, and it provides a distortion-free evaluation of the implant site. However, it is also associated with higher costs and increased radiation exposure. Dynamic and static navigation are equal in accuracy and are both more accurate compared with the freehand method. No benefit in terms of implant survival could be demonstrated within the first 5 years for any specific method.

          Discussion

          A panoramic X-ray with a reference body often provides sufficient imaging and is the primary method for two-dimensional imaging. Cone beam computed tomography with low-dose protocol settings should be used if three-dimensional imaging is needed. Navigational support should be considered in the event of especially complex cases.

          Conclusion

          The guidance technique used for implant placement should be decided on an individual basis. With the increasing availability of three-dimensional imaging, there should also be an increase in awareness of radiation exposure.

          Supplementary Information

          The online version contains supplementary material available at 10.1186/s40729-021-00328-9.

          Related collections

          Most cited references65

          • Record: found
          • Abstract: not found
          • Article: not found

          Current state of the art of computer-guided implant surgery

            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Cone beam computed tomography in implant dentistry: recommendations for clinical use

            Background In implant dentistry, three-dimensional (3D) imaging can be realised by dental cone beam computed tomography (CBCT), offering volumetric data on jaw bones and teeth with relatively low radiation doses and costs. The latter may explain why the market has been steadily growing since the first dental CBCT system appeared two decades ago. More than 85 different CBCT devices are currently available and this exponential growth has created a gap between scientific evidence and existing CBCT machines. Indeed, research for one CBCT machine cannot be automatically applied to other systems. Methods Supported by a narrative review, recommendations for justified and optimized CBCT imaging in oral implant dentistry are provided. Results The huge range in dose and diagnostic image quality requires further optimization and justification prior to clinical use. Yet, indications in implant dentistry may go beyond diagnostics. In fact, the inherent 3D datasets may further allow surgical planning and transfer to surgery via 3D printing or navigation. Nonetheless, effective radiation doses of distinct dental CBCT machines and protocols may largely vary with equivalent doses ranging between 2 to 200 panoramic radiographs, even for similar indications. Likewise, such variation is also noticed for diagnostic image quality, which reveals a massive variability amongst CBCT technologies and exposure protocols. For anatomical model making, the so-called segmentation accuracy may reach up to 200 μm, but considering wide variations in machine performance, larger inaccuracies may apply. This also holds true for linear measures, with accuracies of 200 μm being feasible, while sometimes fivefold inaccuracy levels may be reached. Diagnostic image quality may also be dramatically hampered by patient factors, such as motion and metal artefacts. Apart from radiodiagnostic possibilities, CBCT may offer a huge therapeutic potential, related to surgical guides and further prosthetic rehabilitation. Those additional opportunities may surely clarify part of the success of using CBCT for presurgical implant planning and its transfer to surgery and prosthetic solutions. Conclusions Hence, dental CBCT could be justified for presurgical diagnosis, preoperative planning and peroperative transfer for oral implant rehabilitation, whilst striving for optimisation of CBCT based machine-dependent, patient-specific and indication-oriented variables.
              • Record: found
              • Abstract: found
              • Article: not found

              CBCT-based bone quality assessment: are Hounsfield units applicable?

              CBCT is a widely applied imaging modality in dentistry. It enables the visualization of high-contrast structures of the oral region (bone, teeth, air cavities) at a high resolution. CBCT is now commonly used for the assessment of bone quality, primarily for pre-operative implant planning. Traditionally, bone quality parameters and classifications were primarily based on bone density, which could be estimated through the use of Hounsfield units derived from multidetector CT (MDCT) data sets. However, there are crucial differences between MDCT and CBCT, which complicates the use of quantitative gray values (GVs) for the latter. From experimental as well as clinical research, it can be seen that great variability of GVs can exist on CBCT images owing to various reasons that are inherently associated with this technique (i.e. the limited field size, relatively high amount of scattered radiation and limitations of currently applied reconstruction algorithms). Although attempts have been made to correct for GV variability, it can be postulated that the quantitative use of GVs in CBCT should be generally avoided at this time. In addition, recent research and clinical findings have shifted the paradigm of bone quality from a density-based analysis to a structural evaluation of the bone. The ever-improving image quality of CBCT allows it to display trabecular bone patterns, indicating that it may be possible to apply structural analysis methods that are commonly used in micro-CT and histology.

                Author and article information

                Contributors
                Burkhard-Kunzendorf@gmx.de
                Journal
                Int J Implant Dent
                Int J Implant Dent
                International Journal of Implant Dentistry
                Springer Berlin Heidelberg (Berlin/Heidelberg )
                2198-4034
                27 May 2021
                27 May 2021
                December 2021
                : 7
                : 52
                Affiliations
                GRID grid.412468.d, ISNI 0000 0004 0646 2097, Department of Oral and Maxillofacial Surgery, , University Hospital of Schleswig-Holstein, ; Campus Kiel, Arnold-Heller-Straße 3, 24105 Kiel, Germany
                Author information
                http://orcid.org/0000-0002-8193-8628
                Article
                328
                10.1186/s40729-021-00328-9
                8155130
                34041613
                3e711943-1dfe-4f84-8fa9-d77d15c4504a
                © The Author(s) 2021

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 14 December 2020
                : 18 March 2021
                Categories
                Review
                Custom metadata
                © The Author(s) 2021

                dental implants,cone beam ct,navigation,3-d imaging,2-d imaging

                Comments

                Comment on this article

                Related Documents Log