      Aurícula derecha: un buen aliado en la estimulación ventricular izquierda durante el implante percutáneo de válvula aórtica Translated title: Right atrium: a good ally in left ventricular pacing during transcatheter aortic valve implantation

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          RESUMEN Introducción y objetivos: La estimulación ventricular rápida reduce el gasto cardiaco, proporcionando estabilidad durante el implante percutáneo de válvula aórtica (TAVI). Nuestro objetivo fue evaluar la eficacia y la seguridad de la estimulación ventricular izquierda a través de la guía de alto soporte utilizada para el implante y una guía situada en la aurícula derecha (AD) que actúa como ánodo. Métodos: La estimulación ventricular izquierda se realiza conectando el extremo externo de una guía Safari2 preformada situada en el ventrículo izquierdo al cátodo de un marcapasos temporal, y el ánodo al cuerpo de una guía Emerald insertada en la aurícula mediante un catéter Judkins Right diagnóstico a través de un acceso venoso femoral (punción ecoguiada). El marcapasos se programa con salida máxima (20 V) y sensibilidad anulada. Resultados: Se realizó TAVI transfemoral a 62 pacientes seleccionados (mediana de edad: 79,4 ± 6,5 años) utilizando la técnica de estimulación descrita (25 SAPIEN 3 Ultra, 13 Navitor, 9 ACURATE neo2, 14 Evolut-PRO+ y 1 Myvalve), con éxito en todos los casos (hubo 1 fallo de captura atribuido a la programación del generador del marcapasos). Dos pacientes necesitaron marcapasos transitorio y definitivo posterior por bloqueo auriculoventricular completo durante el procedimiento. No se documentaron complicaciones vasculares derivadas del acceso venoso ni del posicionamiento de la guía en la AD. No aumentaron de manera significativa el tiempo del procedimiento ni la fluoroscopia. La mediana de estancia hospitalaria tras el implante fue de 2 días. Conclusiones: En nuestra serie, la estimulación ventricular izquierda utilizando como ánodo la guía situada en la AD ha demostrado ser una técnica eficaz y segura, sin aumentar significativamente el tiempo de procedimiento, y además aporta la ventaja de disponer de acceso venoso central para un posible marcapasos transitorio urgente.

          Translated abstract

          ABSTRACT Introduction and objectives: Rapid ventricular pacing reduces cardiac output by providing stability during transcatheter aortic valve implantation (TAVI). Our objective is to assess the efficacy and safety profile of left ventricular pacing through the high-support guidewire used for implantation and a guidewire located in the right atrium (RA) functioning as an anode. Methods: Left ventricular pacing is performed by connecting the external end of a Safari2 pre-shaped guidewire located in the left ventricle to the cathode of a temporary pacemaker, and the anode to the body of an Emerald guidewire inserted into the RA using a diagnostic Judkins Right catheter (via ultrasound-guided femoral venous access). Pacemaker was programmed with maximum output (20 V) and null sensitivity. Results: A total of 62 selected patients (median 79.4 ± 6.5 years old) underwent transfemoral TAVI using the pacing technique described (25 patients the SAPIEN 3 Ultra; 13 the Navitor, 9 the ACURATE neo2, 14 the Evolut PRO+, and 1 patient the Myvalve). Procedure was successful in all cases (there was 1 capture failure due to pacemaker programming). Two patients required a temporary and permanent pacemaker due to high-grade atrioventricular block. No vascular complications from venous access were documented, not even from the RA guidewire. Procedural time did not increase significantly, and the median length of stay after implantation was 2 days. Conclusions: In our series, left ventricular pacing using the RA-positioned wire as the anode proved to be effective and safe without increasing procedural time significantly. This procedure also provides the advantage of being able to use the central venous access for possible emergency temporary pacemaker implantation.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: found
          • Article: not found

          Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients

          Among patients with aortic stenosis who are at intermediate or high risk for death with surgery, major outcomes are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. There is insufficient evidence regarding the comparison of the two procedures in patients who are at low risk.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients

            Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

              Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients.
                Bookmark

                Author and article information

                Journal
                recic
                REC: Interventional Cardiology
                REC Interv Cardiol ES
                Sociedad Española de Cardiología (Madrid, Madrid, Spain )
                2604-7306
                2604-7276
                September 2023
                : 5
                : 3
                : 178-184
                Affiliations
                [1] Sevilla orgnameHospital Universitario Virgen del Rocío orgdiv1Área del Corazón orgdiv2Unidad de Hemodinámica y Cardiología Intervencionista, Servicio de Cardiología España
                Article
                S2604-73062023000300004 S2604-7306(23)00500300004
                10.24875/recic.m23000371
                3e8b26fe-0a87-4f6d-a76f-9e4f4e7303b5

                This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

                History
                : 06 February 2023
                : 05 November 2022
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 15, Pages: 7
                Product

                SciELO Spain

                Categories
                Artículos originales

                Right atrium,Left ventricular pacing,Transcatheter aortic valve implantation,Aortic stenosis,Acceso venoso femoral,Aurícula derecha,Estimulación ventricular izquierda,Implante percutáneo de válvula aórtica,Estenosis aórtica,Femoral venous access

                Comments

                Comment on this article