      Heart rate variability stabilization in athletes: towards more convenient data acquisition.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Resting heart rate variability (HRV) is a potentially useful marker to consider for monitoring training status in athletes. However, traditional HRV data collection methodology requires a 5-min recording period preceded by a 5-min stabilization period. This lengthy process may limit HRV monitoring in the field due to time constraints and high compliance demands of athletes. Investigation into more practical methodology for HRV data acquisitions is required. The aim of this study was to determine the time course for stabilization of ECG-derived lnRMSSD from traditional HRV recordings. Ten-minute supine ECG measures were obtained in ten male and ten female collegiate cross-country athletes. The first 5 min for each ECG was separately analysed in successive 1-min intervals as follows: minutes 0-1 (lnRMSSD0-1 ), 1-2 (lnRMSSD1-2 ), 2-3 (lnRMSSD2-3 ), 3-4 (lnRMSSD3-4 ) and 4-5 (lnRMSSD4-5 ). Each 1-min lnRMSSD segment was then sequentially compared to lnRMSSD of the 5- to 10-min ECG segment, which was considered the criterion (lnRMSSDC riterion ). There were no significant differences between each 1-min lnRMSSD segment and lnRMSSDC riterion , and the effect sizes were considered trivial (ES ranged from 0·07 to 0·12). In addition, the ICC for each 1-min segment compared to the criterion was near perfect (ICC values ranged from 0·92 to 0·97). The limits of agreement between the prerecording values and lnRMSSDC riterion ranged from ±0·28 to ±0·45 ms. These results lend support to shorter, more convenient ECG recording procedures for lnRMSSD assessment in athletes by reducing the prerecording stabilization period to 1 min.

          Related collections

          Author and article information

          Journal
          Clin Physiol Funct Imaging
          Clinical physiology and functional imaging
          Wiley-Blackwell
          1475-097X
          1475-0961
          Sep 2016
          : 36
          : 5
          Affiliations
          [1 ] Human Performance Laboratory, Department of Kinesiology, The University of Alabama, Tuscaloosa, AL, USA.
          [2 ] Human Performance Laboratory, Auburn University Montgomery, Montgomery, AL, USA.
          Article
          10.1111/cpf.12233
          25754514
          3f51df54-344a-4b40-89a9-227d04e93008
          History

          vagal,stability,parasympathetic,monitoring,cardiovascular,autonomic

          Comments

          Comment on this article