      Evaluation of surface water characteristics of novel daily disposable contact lens materials, using refractive index shifts after wear

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          Contact lens wearers today spend much time using digital display devices. Contact lens manufacturers are challenged to develop products that account for longer periods of time where blink rate is reduced and tear-film evaporation rate is increased, affecting both visual acuity and comfort. Two manufacturers recently introduced novel daily disposable contact lenses with high surface water content. The objective of the present study was to compare surface water characteristics before and after initial wear of recently introduced nesofilcon A and delefilcon A high surface water lenses with those of etafilcon A lenses.

          Patients and methods

          Twenty healthy subjects wore each of the three lens types studied in a randomly determined order for 15 minutes. After each wearing, lenses were removed and the surface refractive index (RI) of each lens was immediately measured.

          Results

          The mean RI of the unworn delefilcon A lens was 1.34, consistent with water content in excess of 80%. After 15 minutes of wear, the surface RI shifted to 1.43, consistent with its reported 33% bulk water content. In contrast, the mean surface RI of the nesofilcon A lens was 1.38, both initially and after 15 minutes of wear, and that of the etafilcon A lens was 1.41 initially and 1.42 after 15 minutes of wear.

          Conclusion

          The surface of the delefilcon A lens behaves like a high water hydrogel upon insertion but quickly dehydrates to behave like its low-water silicone-hydrogel bulk material with respect to surface water content during wear, while both nesofilcon A and etafilcon A lenses maintain their water content during initial wear. The nesofilcon A lens appears unique among high water lenses in maintaining high surface and bulk water content during wear. This is important because changes in surface RI due to dehydration are reported to lead to visual aberration affecting user experience.

          Related collections

          Most cited references43

          • Record: found
          • Abstract: found
          • Article: not found

          Analysis of blink rate patterns in normal subjects.

          The present study measured the normal blink rate (BR) variations in relation to behavioral tasks in 150 healthy volunteers (70 males and 80 females; aged 35.9 +/- 17.9 years, range 5-87 years). The subjects were videotaped in a standard setting while performing three different tasks: resting quietly, reading a short passage, talking freely. The mean BR was computed during each task; the data were compared by means of analysis of variance and Student's t tests. Mean BR at rest was 17 blinks/min, during conversation it increased to 26, and it was as low as 4.5 while reading. As compared with rest, BR decreased by -55.08% while reading (p rest > reading, which occurred in 101 subjects (67.3%); 34 subjects (22.7%) had the pattern rest > conversation > reading; 12 (8.0%) had the pattern conversation > reading > rest. This study identified three normal behavioral BR patterns and showed that BR is more influenced by cognitive processes than by age, eye color, or local factors. The present findings provide a normal reference for the analysis of BR in movement disorders such as dystonia or tics.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Dry eyes and video display terminals.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Blink rate, blink amplitude, and tear film integrity during dynamic visual display terminal tasks.

              The present study aimed at investigating the influence of the level of dynamism of two different visual display terminal tasks on spontaneous eyeblink rate, blink amplitude, and tear film integrity. A total of 25 healthy, young volunteers participated in the study. Blink rate and blink amplitude were recorded in silent primary gaze conditions and while subjects were playing two computer games of similar cognitive demands but different rate of visual information presentation. For each experimental condition, tear volume was evaluated by measuring meniscus height and with the red phenol thread test. Fluorescein and non-invasive break-up time tests, as well as the observation of interference patterns and the estimation of the dry area extension, were employed to assess tear stability. Statistically significant differences were revealed in blink rate (F = 595.85, p < 0.001) and blink amplitude (χ(2) = 34.00, p < 0.001), with blink rate during fast- and slow-paced game play decreasing to almost 1/3 and 1/2 of baseline levels, respectively, and with a larger percentage of incomplete blinks during dynamic tasks. Fluorescein and non-invasive break-up time tests and dry area extension were able to differentiate between experimental conditions in general (F = 408.42, p < 0.001; F = 163.49, p < 0.001; χ(2) = 20.74, p < 0.001), as well as between fast- and slow-paced games, thus suggesting that tear quality was more affected than tear volume. Blink rate, blink amplitude, and tear film stability were compromised during the most dynamic visual display terminal task, suggesting a negative influence of not only the cognitive aspects of the task, but also of the rate at which new visual information is presented. Frequent breaks and blinking awareness training are recommended for visual display terminal users requiring prolonged periods of visually demanding dynamic computer play or work.
                Bookmark

                Author and article information

                Journal
                Clin Ophthalmol
                Clin Ophthalmol
                Clinical Ophthalmology
                Clinical Ophthalmology (Auckland, N.Z.)
                Dove Medical Press
                1177-5467
                1177-5483
                2015
                22 October 2015
                : 9
                : 1973-1979
                Affiliations
                [1 ]Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA
                [2 ]J Chinn LLC, Lafayette, CO, USA
                Author notes
                Correspondence: Joseph Chinn, J Chinn LLC, 404 Lone Eagle Pt, Lafayette, CO 80026, USA, Tel +1 303 604 6026, Email jchinnllc@ 123456q.com
                Article
                opth-9-1973
                10.2147/OPTH.S90376
                4622526
                26543349
                4031c475-dd35-41ee-84ea-8b5326c5705b
                © 2015 Schafer et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License

                The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.

                History
                Categories
                Original Research

                Ophthalmology & Optometry
                contact lens dehydration,poloxamer,visual acuity,wetting
                Ophthalmology & Optometry
                contact lens dehydration, poloxamer, visual acuity, wetting

                Comments

                Comment on this article