      Wear and lysis is the problem in modular TKA in the young OA patient at 10 years.

      Clinical Orthopaedics and Related Research
      Adult, Age Factors, Arthroplasty, Replacement, Knee, adverse effects, instrumentation, Female, Humans, Iowa, Kaplan-Meier Estimate, Knee Prosthesis, Male, Middle Aged, Osteoarthritis, Knee, radiography, surgery, Osteolysis, etiology, Prosthesis Design, Prosthesis Failure, Reoperation, Retrospective Studies, Stress, Mechanical, Time Factors, Treatment Outcome

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Most long-term followup studies of younger patients who underwent TKA include a relatively high percentage of rheumatoid patients, whose function and implant durability may differ from those with osteoarthritis (OA). The purpose of this study was to evaluate the minimum 10 year followup of TKA performed in more active patients with OA, using modular tibial components, to determine the durability of that construct. Specifically, we determined (1) survivorship; (2) revision rates; (3) functional scores; and (4) rates of radiographic failure at a minimum 10 year followup. We retrospectively reviewed 59 patients (67 knees) with OA who underwent primary total knee arthroplasty with posterior cruciate retaining (27%) or posterior cruciate substituting (73%) components which had modular tibial trays. Patients were evaluated clinically for need of revision and Knee Society, SF-36 and WOMAC scores as well as UCLA and Tegner activity scores. Radiographs were evaluated for loosening and osteolysis. The minimum followup of living patients was 10 years (mean, 12.4 years; range, 10 to 18.4 years). Ten patients (11 knees) died; two patients (2 knees) were lost to followup. Ten patients (11 knees; 16%) had revisions for aseptic loosening and/or osteolysis. Thirty-one patients (65%) were still performing moderate labor or sports activities. The average UCLA score was 5.5 (range, 2-9). No nonrevised knee demonstrated radiographic loosening. Most patients in this active patient population continued to have acceptable function although 16% underwent revision for wear and/or osteolysis. Isolated tibial insert exchange alone was performed in four of the 11 (36%) revised knees. These data should provide comparison for total knee arthroplasties performed in younger patients with newer designs and newer bearing materials. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

          Related collections

          Author and article information

          Comments

          Comment on this article