      Application of supercritical fluid chromatography to characterize a labile digitalis-like factor.

      Hypertension
      Cardenolides, Chromatography, Gas, methods, Chromatography, High Pressure Liquid, Digoxin, Enzyme Inhibitors, isolation & purification, pharmacology, Humans, Hypertension, complications, metabolism, Kidney Failure, Chronic, etiology, Ouabain, Saponins, chemistry, Sodium-Potassium-Exchanging ATPase, antagonists & inhibitors

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A sodium pump inhibitor (digitalis-like factor), isolated from the peritoneal dialysate of volume-expanded, hypertensive patients with kidney failure who were treated with this dialysis modality, was further purified and characterized by means of supercritical fluid chromatography, a separation technique whose application to very-low-concentration biomolecules is new. Previous studies suggested that after high-performance liquid chromatography (HPLC) purification, this inhibitor was the only factor correlated with volume status and blood pressure in these patients. When this same HPLC fraction was furthered purified on 2-dimensional supercritical fluid chromatography, a single peak coeluted with [Na,K]ATPase inhibitory activity. When split specimens were used, there was a strict correlation between the peak area, measured by flame ionization detection, and activity (n=10, R=0.98, P=0.00001). Inhibitory activity after supercritical fluid chromatography was still correlated with the degree of volume expansion of donor patients (P=0.01). After HPLC purification, this volume-sensitive inhibitor was chemically labile. With further purification on supercritical fluid chromatography, the active peak was still labile with comparable half-life. Supercritical fluid chromatography coupled with flame ionization detection provided an estimate of the amount of the inhibitor present. Again using split specimens, we determined that the labile digitalis-like factor was approximately 30-fold more effective than ouabain in inhibiting renal [Na,K]ATPase activity and >/=500 times more effective than ouabain in causing vascular smooth muscle contraction. The data suggest that we have purified to homogeneity a labile digitalis-like factor that is readily distinguished from ouabain or bufalin, based on chromatographic characteristics, chemical lability, and a much lower effective concentration for its biological activity.

          Related collections

          Author and article information

          Comments

          Comment on this article