      Rare early prosthesis obstruction after mitral valve replacement: a case report and literature review

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          As a dreadful complication after the mechanical heart valve replacement, prosthetic valve obstruction caused by pannus formation occurs increasingly with time. The authors here present a case of 42-year-old woman who was urgently admitted to hospital with acute heart failure symptoms due to the mechanical mitral valve failure only 3 months after surgery. Transthoracic and transesophageal echocardiography demonstrated that the bileaflet of the mitral prosthesis were completely immobilized with only a small transvalvular jet remained. During the reoperation, the reason of the prosthetic valve obstruction was attributed to the noncircular pannus ingrowth extending from the atrioventricular side. For a better understanding of the prosthetic valve dysfunction caused by pannus formation, the authors then compile a literature review to briefly discuss the status quo of the clinical characteristics of this uncommon complication.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: not found

          Obstruction of St Jude Medical valves in the aortic position: histology and immunohistochemistry of pannus.

          This study aims to reveal the morphological, histological, and immunohistochemical mechanism of pannus formation using resected pannus tissue from patients with prosthetic valve dysfunction. Eleven patients with prosthetic valve (St Jude Medical valve) dysfunction in the aortic position who underwent reoperation were studied. We used specimens of resected pannus for histological staining (hematoxylin and eosin, Grocott's, azan, elastica van Gieson) and immunohistochemical staining (transforming growth factor-beta, transforming growth factor-beta receptor 1, alpha-smooth muscle actin, desmin, epithelial membrane antigen, CD34, factor VIII, CD68KP1, matrix metalloproteinase-1, matrix metalloproteinase-3, and matrix metalloproteinase-9). Pannus without thrombus was observed at the periannulus of the left ventricular septal side; it extended into the pivot guard, interfering with the movement of the straight edge of the leaflet. The histological staining demonstrated that the specimens were mainly constituted with collagen and elastic fibrous tissue accompanied by endothelial cells, chronic inflammatory cells infiltration, and myofibroblasts. The immunohistochemical findings showed significant expression of transforming growth factor-beta, transforming growth factor-beta receptor 1, CD34, and factor VIII in the endothelial cells of the lumen layer; strong transforming growth factor-beta receptor 1, alpha-smooth muscle actin, desmin, and epithelial membrane antigen in the myofibroblasts of the media layer; and transforming growth factor-beta, transforming growth factor-beta receptor 1, and CD68KP1 in macrophages of the stump lesion. Pannus appeared to originate in the neointima in the periannulus of the left ventricular septum. The structure of the pannus consisted of myofibroblasts and an extracellular matrix such as collagen fiber. The pannus formation after prosthetic valve replacement may be associated with a process of periannular tissue healing via the expression of transforming growth factor-beta.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Reoperations for acute prosthetic thrombosis and pannus: an assessment of rates, relationship and risk.

            Mechanical valvular prostheses have the advantage of longevity but carry a risk of thrombosis which is dependant on valve design, materials and host-related interface. While pannus is common to both biologic and mechanical valves, acute prosthetic thrombosis is mostly a complication of mechanical valves; therefore we investigated to find rates and risk of these obstructive complications. Between 1/1/70 and 31/12/97, 2680 patients received at least one mechanical prosthesis in the aortic or mitral or tricuspid position and a total of 3014 operations were performed. Follow-up included 18523 years and was 98% complete. Incidence rates, Kaplan-Meier estimates, modeling of the hazard and multivariate analysis in the hazard domain were used in the analysis. Overall survival was 76%, 64%, 51%, 38.5% and 29% at 5, 10, 15, 20 and 25 years, respectively. It was significantly better in aortic than in mitral than in double prosthesis. 290 patients received a single reoperation, 37 a second, six a third and one a fourth reoperation. Two-hundred and fifty-one of these reoperations were exclusively due to malfunction of mechanical prosthesis, nine to malfunction of both mechanic and biologic prostheses. Most frequent reoperative indications was dehiscence (133), pannus (48) and thrombosis (29). The linearized rate of reoperations for pannus was 0.24%/patient per year, for valvular thrombosis 0.15%/patient per year. The shape of the thrombotic hazard was constant (at random) and the relative risk 12 times higher for tricuspid prosthesis, seven times higher for mitral prosthesis. Multivariate analysis controlling for prosthetic position, age, sex and prosthetic size, showed a 67% risk reduction with larger prosthesis (>27 mm), a 69% risk reduction with the Sorin tilting disk prosthesis and an 83% risk reduction with the bileaflet prosthesis. Pannus hazard shows a delayed exponential rise and was two times higher in tricuspid and three times higher in mitral position. Multivariate analysis showed a 50% risk reduction with larger prosthesis, an 11 times higher hazard of old (caged-disk, caged ball) prosthesis and a three times higher hazard of Lillehei-Kaster prosthesis. Reoperation for thrombosis has a 62% perioperative (30 days) survival compared to 92% survival of pannus reoperation. Mechanical valves have a low incidence of reoperation, mostly for prosthetic dehiscence. Pannus development is the next frequent complication increasing with time since implant, therefore in this series it was related to old valvular models and tilting disk prosthesis, with longer follow-up. Acute thrombosis occurs significantly earlier than pannus formation. Despite shorter follow-up we are therefore confident that bileaflet prostheses are less prone to this complication and pannus is a rare early etiologic factor. Thrombosis has very high operative risk as compared to pannus, justifying the present trend to thrombolysate selected cases.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Prediction of thrombus-related mechanical prosthetic valve dysfunction using transesophageal echocardiography.

              Identification of thrombus-related mechanical prosthetic valve dysfunction (MPVD) has important therapeutic implications. We sought to develop an algorithm, combining clinical and echocardiographic parameters, for prediction of thrombus-related MPVD in a series of 53 patients (24 men, age 52 +/- 16 years) who had intraoperative diagnosis of thrombus or pannus from 1992 to 1997. Clinical and echocardiographic parameters were analyzed to identify predictors of thrombus and pannus. Prevalence of thrombus and diagnostic yields relative to the number of predictors were determined. There were 22 patients with thrombus, 19 patients with pannus, and 12 patients with both. Forty-two of 53 masses were visualized using transesophageal echocardiography (TEE), including 29 of 34 thrombi or both thrombi and panni and 13 of 19 isolated panni. Predictors of thrombus or mixed presentation include mobile mass (p = 0.009), attachment to occluder (p = 0.02), elevated gradients (p = 0.04), and an international normalized ratio of or = 1 predictor. The prevalence of thrombus in the presence of or = 3 predictors is 14%, 69%, and 91%, respectively. Thus, TEE is sensitive in the identification of abnormal mass in the setting of MPVD. An algorithm based on clinical and transesophageal echocardiographic predictors may be useful to estimate the likelihood of thrombus in the setting of MPVD. In the presence of > or = 3 predictors, the probability of thrombus is high.
                Bookmark

                Author and article information

                Contributors
                Journal
                J Cardiothorac Surg
                J Cardiothorac Surg
                Journal of Cardiothoracic Surgery
                BioMed Central
                1749-8090
                2012
                2 July 2012
                : 7
                : 64
                Affiliations
                [1 ]Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Cheng Du, People’s Republic of China
                Article
                1749-8090-7-64
                10.1186/1749-8090-7-64
                3485153
                22747990
                42974aa3-5a85-4580-910e-1b1099ccc72e
                Copyright ©2012 Shi et al.; licensee BioMed Central Ltd.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 9 December 2011
                : 19 May 2012
                Categories
                Case Report

                Surgery
                Surgery

                Comments

                Comment on this article