      Comparison of endovascular treatment for middle cerebral artery aneurysm with a low-profile visualized intraluminal support stent or pipeline embolization device

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of the present study was to evaluate the safety and effectiveness of low-profile visualized intraluminal support (LVIS) stent and the pipeline embolization device (PED) for middle cerebral artery (MCA) aneurysm treatment. Data of patients with MCA aneurysms who received endovascular treatment with LVIS stent or PED added to the hospital's database between August 2016 and March 2018 were retrospectively collected, and the clinical results and angiographic outcomes were evaluated. A total of 43 patients were included in the study, of whom 23 received LVIS stents and 20 received PED. The rate of complete occlusion was similar in the two groups at 6 months post-treatment (90.9 vs. 88.9%; P=0.832). Peri-operative complications were more frequent in the PED group; however, the LVIS group had more ischemic symptoms during the long-term follow-up. A larger aneurysm size (P=0.032) was associated with recanalization in the two groups. In conclusion, the LVIS stent and PED had acceptable rates of complete occlusion and aneurysm size was an independent predictor for recanalization. LVIS is more effective during the peri-operative period, while PED appears to have higher long-term safety.

          Related collections

          Most cited references46

          • Record: found
          • Abstract: found
          • Article: not found

          The durability of endovascular coiling versus neurosurgical clipping of ruptured cerebral aneurysms: 18 year follow-up of the UK cohort of the International Subarachnoid Aneurysm Trial (ISAT)

          Summary Background Previous analyses of the International Subarachnoid Aneurysm Trial (ISAT) cohort have reported on the risks of recurrent subarachnoid haemorrhage and death or dependency for a minimum of 5 years and up to a maximum of 14 years after treatment of a ruptured intracranial aneurysm with either neurosurgical clipping or endovascular coiling. At 1 year there was a 7% absolute and a 24% relative risk reduction of death and dependency in the coiling group compared with the clipping group, but the medium-term results showed the increased need for re-treatment of the target aneurysm in the patients given coiling. We report the long-term follow-up of patients in this UK cohort. Methods In ISAT, patients were randomly allocated to either neurosurgical clipping or endovascular coiling after a subarachnoid haemorrhage, assuming treatment equipoise, between Sept 12, 1994, and May 1, 2002. We followed up 1644 patients in 22 UK neurosurgical centres for death and clinical outcomes for 10·0–18·5 years. We assessed dependency as self-reported modified Rankin scale score obtained through yearly questionnaires. Data for recurrent aneurysms and rebleeding events were collected from questionnaires and from hospital and general practitioner records. The Office for National Statistics supplied data on deaths. This study is registered, number ISRCTN49866681. Findings At 10 years, 674 (83%) of 809 patients allocated endovascular coiling and 657 (79%) of 835 patients allocated neurosurgical clipping were alive (odds ratio [OR] 1·35, 95% CI 1·06–1·73). Of 1003 individuals who returned a questionnaire at 10 years, 435 (82%) patients treated with endovascular coiling and 370 (78%) patients treated with neurosurgical clipping were independent (modified Rankin scale score 0–2; OR 1·25; 95% CI 0·92–1·71). Patients in the endovascular treatment group were more likely to be alive and independent at 10 years than were patients in the neurosurgery group (OR 1·34, 95% CI 1·07–1·67). 33 patients had a recurrent subarachnoid haemorrhage more than 1 year after their initial haemorrhage (17 from the target aneurysm). Interpretation Although rates of increased dependency alone did not differ between groups, the probability of death or dependency was significantly greater in the neurosurgical group than in the endovascular group. Rebleeding was more likely after endovascular coiling than after neurosurgical clipping, but the risk was small and the probability of disability-free survival was significantly greater in the endovascular group than in the neurosurgical group at 10 years. Funding UK Medical Research Council.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Endovascular treatment of intracranial aneurysms: current status.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry.

              The development of self-expanding stents dedicated to intracranial use has significantly widened the applicability of endovascular therapy to many intracranial aneurysms that would otherwise have been untreatable by endovascular techniques. Recent Food and Drug Administration approval of the Enterprise Vascular Reconstruction Device and Delivery System (Cordis) has added a new option for self-expanding stent-assisted intracranial aneurysm coiling. The authors established a collaborative registry across multiple institutions to rapidly provide largevolume results regarding initial experience in using the Enterprise in real-world practice. Ten institutions (University at Buffalo, Thomas Jefferson University, University of Florida, Cleveland Clinic, Northwestern University, West Virginia University, University of Puerto Rico, Albany Medical Center Hospital, the Neurological Institute of Savannah, and the Barrow Neurological Institute) have provided consecutive data regarding their initial experience with the Enterprise. In total, 141 patients (119 women) with 142 aneurysms underwent 143 attempted stent deployments. The use of Enterprise assistance with aneurysm coiling was associated with a 76% rate of > or = 90% occlusion. An inability to navigate or deploy the stent was experienced in 3% of cases, as well as a 2% occurrence of inaccurate deployment. Procedural data demonstrated a 6% temporary morbidity, 2.8% permanent morbidity, and 2% mortality (0.8% unruptured, 12% ruptured). The authors report initial results of the largest series to date in using the Enterprise for intracranial aneurysm treatment. The Enterprise is associated with a high rate of successful navigation and low occurrence of inaccurate stent deployment. The overall morbidity and mortality rates were low; however, caution should be exercised when considering Enterprise deployment in patients with subarachnoid hemorrhage as the authors' experience demonstrated a high rate of associated hemorrhagic complications leading to death.
                Bookmark

                Author and article information

                Journal
                Exp Ther Med
                Exp Ther Med
                ETM
                Experimental and Therapeutic Medicine
                D.A. Spandidos
                1792-0981
                1792-1015
                September 2019
                16 July 2019
                16 July 2019
                : 18
                : 3
                : 2072-2078
                Affiliations
                Department of Neurosurgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang 310016, P.R. China
                Author notes
                Correspondence to: Professor Peng Lu, Department of Neurosurgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Road, Hangzhou, Zhejiang 310016, P.R. China, E-mail: doclupeng@ 123456zju.edu.cn
                Article
                ETM-0-0-7775
                10.3892/etm.2019.7775
                6676140
                43c75eaf-3d44-49fb-90c9-b285988d39d0
                Copyright: © Lu et al.

                This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

                History
                : 09 September 2018
                : 12 April 2019
                Categories
                Articles

                Medicine
                middle cerebral artery aneurysm,low-profile visualized intraluminal support,retrospective study,pipeline embolization device