      Setup errors in radiation therapy for thoracic tumor patients of different body mass index

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          To assess the setup errors in radiation therapy for thoracic tumors patients of different somatotypes, and to seek an individualized mathematical basis for defining the planning target volume ( PTV).

          Methods

          Sixty patients with thoracic tumors were divided into four somatotypes according to their body mass index ( BMI), and their body positions were setup by two groups of technicians independently. CT simulations were performed and the reconstructed radiography was digitally generated as reference images for location verification and error measurement. By setting positioning error ranges, the within‐range positioning correction rate was compared among groups.

          Results

          Position setups for patients in the emaciated group, moderate group, and overweight group were relatively stable (with minor setup error differences between the two groups of technicians). In emaciated group, moderate group, overweight group, and obese group, setup errors in the right–left direction (R‐L) were 2.2 ± 1.3 mm, 2.2 ± 1.6 mm, 3.9 ± 3.1 mm, and 8.8 ± 3.5 mm, respectively; whereas the setup errors in the four groups in the superior–inferior(S‐I) direction were 2.4 ± 1.8 mm, 2.1 ± 1.9 mm, 3.2 ± 2.6 mm, and 5.4 ± 3.5 mm, and in the anterior–posterior (A‐P) direction were 2.2 ± 1.7 mm, 1.9 ± 1.9 mm, 3.2 ± 2.9 mm, and 6.2 ± 4.2 mm, respectively. Moreover, in the moderate group, the positioning correction rate in the three directions (R‐L, S‐I, and A‐P) was 20%, 9%, 8% within the error range of 5–10 mm, and 3%, 0%, 1% with a more than 10 mm error range. However, in overweight group and obese group, the positioning correction rate in these three directions (also with a more than 10 mm error range) was 23%, 27%, 19% and 21%, 16%, 23%, respectively.

          Conclusions

          In radiation therapy for patients with thoracic tumors, the definition of PTV should be individualized. Meanwhile, with the increase in BMI, positioning correction rate has a tendency to rise too.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: not found

          Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors.

          Using daily setup variation measured from an electronic portal imaging device (EPID), radiation treatment of the individual patient can be adaptively reoptimized during the course of therapy. In this study, daily portal images were retrospectively examined to: (a) determine the number of initial days of portal imaging required to give adequate prediction of the systematic and random setup errors; and (b) explore the potential of using the prediction as feedback to reoptimize the individual treatment part-way through the treatment course. Daily portal images of 64 cancer patients, whose treatment position was not adjusted during the course of treatment, were obtained from two independent clinics with similar setup procedures. Systematic and random setup errors for each patient were predicted using different numbers of initial portal measurements. The statistical confidence of the predictions was tested to determine the number of daily portal measurements needed to give reasonable predictions. Two treatment processes were simulated to examine the potential opportunity for setup margin reduction and dose escalation. The first process mimicked a conventional treatment. A constant margin was assigned to each treatment field to compensate for the average setup error of the patient population. A treatment dose was then prescribed with reference to a fixed normal tissue tolerance, and then fixed in the entire course of treatment. In the second process, the same treatment fields and prescribed dose were used only for the initial plan and treatment. After several initial days of treatments, the treatment field shape and position were assumed to be adaptively modified using a computer-controlled multileaf collimator (MLC) in light of the predicted systematic and random setup errors. The prescribed dose was then escalated until the same normal tissue tolerance, as determined in the first treatment process, was reached. The systematic setup error and the random setup error were predicted to be within +/-1 mm for the former and +/-0.5 mm for the latter at a > or = 95% confidence level using < or = 9 initial daily portal measurements. In the study, a large number of patients could be treated using a smaller field margin if the adaptive modification process were used. Simulation of the adaptive modification process for prostate treatment demonstrates that additional treatment dose could be safely applied to 64% of patients. The adaptive modification process represents a different approach for use of on-line portal images. The portal imaging information from the initial treatments is used as feedback for reoptimization of the treatment plan, rather than adjustment of the treatment setup. Results from the retrospective study show that the treatment of individual patient can be improved with the adaptive modification process.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Inverse planning in three-dimensional conformal and intensity-modulated radiotherapy of mid-thoracic oesophageal cancer.

            The aim of this study is to demonstrate the use of inverse planning in three-dimensional conformal radiation therapy (3DCRT) of oesophageal cancer patients and to evaluate its dosimetric results by comparing them with forward planning of 3DCRT and inverse planning of intensity-modulated radiotherapy (IMRT). For each of the 15 oesophageal cancer patients in this study, the forward 3DCRT, inverse 3DCRT and inverse IMRT plans were produced using the FOCUS treatment planning system. The dosimetric results and the planner's time associated with each of the treatment plans were recorded for comparison. The inverse 3DCRT plans showed similar dosimetric results to the forward plans in the planning target volume (PTV) and organs at risk (OARs). However, they were inferior to that of the IMRT plans in terms of tumour control probability and target dose conformity. Furthermore, the inverse 3DCRT plans were less effective in reducing the percentage lung volume receiving a dose below 25 Gy when compared with the IMRT plans. The inverse 3DCRT plans delivered a similar heart dose as in the forward plans, but higher dose than the IMRT plans. The inverse 3DCRT plans significantly reduced the operator's time by 2.5 fold relative to the forward plans. In conclusion, inverse planning for 3DCRT is a reasonable alternative to the forward planning for oesophageal cancer patients with reduction of the operator's time. However, IMRT has the better potential to allow further dose escalation and improvement of tumour control.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Set-up verification and 2-dimensional electronic portal imaging device dosimetry during breath hold compared with free breathing in breast cancer radiation therapy.

              To compare set-up and 2-dimensional (2D) electronic portal imaging device (EPID) dosimetry data of breast cancer patients treated during voluntary moderately deep inspiration breath hold (vmDIBH) and free breathing (FB).
                Bookmark

                Author and article information

                Contributors
                lixingde@126.com
                Journal
                J Appl Clin Med Phys
                J Appl Clin Med Phys
                10.1002/(ISSN)1526-9914
                ACM2
                Journal of Applied Clinical Medical Physics
                John Wiley and Sons Inc. (Hoboken )
                1526-9914
                01 March 2018
                May 2018
                : 19
                : 3 ( doiID: 10.1002/acm2.2018.19.issue-3 )
                : 27-31
                Affiliations
                [ 1 ] Department of Oncology Cangzhou Central Hospital Cangzhou Hebei China
                [ 2 ] Department of Radiation Oncology Third Hospital of Hebei Medical University Cangzhou Hebei China
                [ 3 ] Department of Radiation Oncology Cangzhou Central Hospital Cangzhou, Hebei China
                Author notes
                [*] [* ] Author to whom correspondence should be addressed. Xingde Li

                E‐mail: lixingde@ 123456126.com

                Article
                ACM212270
                10.1002/acm2.12270
                5978940
                29493070
                43f5aafa-6512-4804-a547-c6e91ff011cd
                © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine

                This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

                History
                : 05 March 2017
                : 19 October 2017
                : 14 November 2017
                Page count
                Figures: 1, Tables: 3, Pages: 5, Words: 3928
                Categories
                87.53.Kn
                Radiation Oncology Physics
                Radiation Oncology Physics
                Custom metadata
                2.0
                acm212270
                May 2018
                Converter:WILEY_ML3GV2_TO_NLMPMC version:version=5.4.0 mode:remove_FC converted:31.05.2018

                body mass index (bmi),radiation therapy,setup errors,thoracic tumor

                Comments

                Comment on this article