      Recent developments in intraocular lens power calculation methods—update 2020

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          For many decades only a few formulas have been available to calculate the intraocular lens (IOL) power for patients undergoing cataract surgery: the Haigis, Hoffer Q, Holladay 1 and 2 and SRK/T. In recent years, several new formulas for IOL power calculation have been introduced with the aim of improving the accuracy of refraction prediction in eyes undergoing cataract surgery. These include the Barrett Universal II, the Emmetropia Verifying Optical (EVO), the Kane, the Næser 2, the Olsen, the Panacea, the Pearl DGS, the Radial Basis Function (RBF), the T2 and the VRF formulas. Although most of them are unpublished so that their structure is unknown, we give an overview of each formula and report the results of the studies that have compared them. Their performance in short and long eyes is provided and a special focus is given on the issue of segmented axial length, which is a promising method to obtain more accurate outcomes in short and long eyes. Here, the group refractive index originally developed for the IOLMaster may not represent the best method to convert the optical path length into a physical distance. The issue of posterior and total corneal astigmatism (TCA) is discussed in relation to toric IOLs; the latest formulas for toric IOLs and their results are also reported.

          Related collections

          Most cited references70

          • Record: found
          • Abstract: found
          • Article: not found

          Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis.

          The precision of intraocular lens (IOL) calculation is essentially determined by the accuracy of the measurement of axial length. In addition to classical ultrasound biometry, partial coherence interferometry serves as a new optical method for axial length determination. A functional prototype from Carl Zeiss Jena implementing this principle was compared with immersion ultrasound biometry in our laboratory. In 108 patients attending the biometry laboratory for planning of cataract surgery, axial lengths were additionally measured optically. Whereas surgical decisions were based on ultrasound data, we used postoperative refraction measurements to calculate retrospectively what results would have been obtained if optical axial length data had been used for IOL calculation. For the translation of optical to geometrical lengths, five different conversion formulas were used, among them the relation which is built into the Zeiss IOL-Master. IOL calculation was carried out according to Haigis with and without optimization of constants. On the basis of ultrasound immersion data from our Grieshaber Biometric System (GBS), postoperative refraction after implantation of a Rayner IOL type 755 U was predicted correctly within +/- 1 D in 85.7% and within +/- 2 D in 99% of all cases. An analogous result was achieved with optical axial length data after suitable transformation of optical path lengths into geometrical distances. Partial coherence interferometry is a noncontact, user- and patient-friendly method for axial length determination and IOL planning with an accuracy comparable to that of high-precision immersion ultrasound.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Accuracy of Intraocular Lens Calculation Formulas.

            To compare the accuracy of intraocular lens (IOL) calculation formulas (Barrett Universal II, Haigis, Hoffer Q, Holladay 1, Holladay 2, Olsen, and SRK/T) in the prediction of postoperative refraction using a single optical biometry device.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Contribution of posterior corneal astigmatism to total corneal astigmatism.

              To determine the contribution of posterior corneal astigmatism to total corneal astigmatism and the error in estimating total corneal astigmatism from anterior corneal measurements only using a dual-Scheimpflug analyzer. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Case series. Total corneal astigmatism was calculated using ray tracing, corneal astigmatism from simulated keratometry, anterior corneal astigmatism, and posterior corneal astigmatism, and the changes with age were analyzed. Vector analysis was used to assess the error produced by estimating total corneal astigmatism from anterior corneal measurements only. The study analyzed 715 corneas of 435 consecutive patients. The mean magnitude of posterior corneal astigmatism was -0.30 diopter (D). The steep corneal meridian was aligned vertically (60 to 120 degrees) in 51.9% of eyes for the anterior surface and in 86.6% for the posterior surface. With increasing age, the steep anterior corneal meridian tended to change from vertical to horizontal, while the steep posterior corneal meridian did not change. The magnitudes of anterior and posterior corneal astigmatism were correlated when the steeper anterior meridian was aligned vertically but not when it was aligned horizontally. Anterior corneal measurements underestimated total corneal astigmatism by 0.22 @ 180 and exceeded 0.50 D in 5% of eyes. Ignoring posterior corneal astigmatism may yield incorrect estimation of total corneal astigmatism. Selecting toric intraocular lenses based on anterior corneal measurements could lead to overcorrection in eyes that have with-the-rule astigmatism and undercorrection in eyes that have against-the-rule astigmatism. The authors received research support from Ziemer Group. In addition, Dr. Koch has a financial interest with Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Calhoun Vision, Inc., NuLens, and Optimedica Corp. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Journal
                Ann Transl Med
                Ann Transl Med
                ATM
                Annals of Translational Medicine
                AME Publishing Company
                2305-5839
                2305-5847
                November 2020
                November 2020
                : 8
                : 22
                : 1553
                Affiliations
                [1 ]IRCCS - G.B. Bietti Foundation , Rome, Italy;
                [2 ]Ophthalmology Unit, S. Orsola-Malpighi University Hospital, University of Bologna , Bologna, Italy;
                [3 ]Stein Eye Institute, University of California , Los Angeles, CA, USA;
                [4 ]St. Mary’s Eye Center , Santa Monica, CA, USA
                Author notes

                Contributions: (I) Conception and design: G Savini; (II) Administrative support: G Savini; (III) Provision of study materials or patients: None; (IV) Collection and assembly of data: None; (V) Data analysis and interpretation: None; (VI) Manuscript writing: All authors; (VII) Final approval of manuscript: All authors.

                Correspondence to: Giacomo Savini, MD. IRCCS - G.B. Bietti Foundation, Via Livenza, 3 – Rome, Italy. Email: giacomo.savini@ 123456fondazionebietti.it .
                Article
                atm-08-22-1553
                10.21037/atm-20-2290
                7729321
                33313298
                4508579e-5a88-411c-83d1-d3904ab6a8bb
                2020 Annals of Translational Medicine. All rights reserved.

                Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0.

                History
                : 07 March 2020
                : 24 July 2020
                Categories
                Review Article on Recent Developments in Cataract Surgery

                lenses,intraocular,biometry,cataract
                lenses, intraocular, biometry, cataract

                Comments

                Comment on this article