      Comparison of an automated nucleic acid extraction system with the column-based procedure

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Here, we assessed the extraction efficiency of a deployable bench-top nucleic acid extractor EZ1 in comparison to the column-based approach with complex sample matrices.A total of 48 EDTA blood samples and 81 stool samples were extracted by EZ1 automated extraction and the column-based QIAamp DNA Mini Kit. Blood sample extractions were assessed by two real-time malaria PCRs, while stool samples were analyzed by six multiplex real-time PCR assays targeting bacterial, viral, and parasitic stool pathogens. Inhibition control PCR testing was performed as well.In total, 147 concordant and 13 discordant pathogen-specific PCR results were obtained. The latter comprised 11 positive results after column-based extraction only and two positive results after EZ1 extraction only. EZ1 extraction showed a higher frequency of inhibition. This phenomenon was, however, inconsistent for the different PCR schemes. In case of concordant PCR results, relevant differences of cycle threshold numbers for the compared extraction schemes were not observed.Switches from well-established column-based extraction to extraction with the automated EZ1 system do not lead to a relevantly reduced yield of target DNA when complex sample matrices are used. If sample inhibition is observed, column-based extraction from another sample aliquot may be considered.

          Related collections

          Author and article information

          Journal
          1886
          122234
          European Journal of Microbiology and Immunology
          Akadémiai Kiadó
          2062-509X
          2062-8633
          1 March 2015
          26 March 2015
          : 5
          : 1 ( otherID: VRG7W6904000 )
          : 94-102
          Affiliations
          [ 1 ] German Armed Forces Hospital of Hamburg Department of Tropical Medicine at the Bernhard Nocht Institute Bernhard Nocht street 74 D-20359 Hamburg Germany
          [ 2 ] University Medicine Rostock Institute for Medical Microbiology, Virology and Hygiene Rostock Germany
          Article
          A1012161L4704H71
          10.1556/eujmi-d-14-00040
          4397851
          25883797
          451d3500-96a8-4f08-b475-da9e3b993e59
          History
          Categories
          Original Article

          Medicine,Immunology,Health & Social care,Microbiology & Virology,Infectious disease & Microbiology
          RNA,EZ1,automate,nucleic acid extraction,DNA,column,inhibition