      Variability of automated carotid intima-media thickness measurements by novice operators.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Carotid intima-media thickness (C-IMT) measurements provide a non-invasive assessment of subclinical atherosclerosis. The aim of the study was to assess the inter- and intra-observer variability of automated C-IMT measurements undertaken by two novice operators using the Panasonic CardioHealth Station. Participants were free from cardio-metabolic disease, and each underwent serial bilateral C-IMT ultrasound measurements. Immediate interoperator measurement variability was calculated by comparing initial measurements taken by two operators. Immediate retest variability was calculated from two consecutive measurements and longer term variability was assessed by conducting a further scan 1 week later. Fifty apparently healthy participants (n = 20 females), aged 26·2 ± 5·0 years, were recruited. Operator 1 recorded a median (interquartile range) right and left-sided C-IMT of 0·471 mm (0·072 mm) and 0·462 mm (0·047 mm). Female's right and left C-IMT were 0·442 mm (0·049 mm) and 0·451 mm (0·063 mm), respectively. The limits of agreement (LoA) for immediate interoperator variability were -0·063 to 0·056 mm (mean bias -0·003 mm). Operator 1's immediate retest intra-operator LoA were -0·057 to 0·046 mm (mean bias was -0·005 mm). One-week LoA were -0·057 to 0·050 mm (mean bias -0·003 mm). Operator 2 recorded median right and left-sided C-IMT of 0·467 mm (0·089 mm) and 0·458 mm (0·046 mm) for males, respectively, whilst female measurements were 0·441 mm (0·052 mm) and 0·444 mm (0·054 mm), respectively. Operator 2's intra-operator immediate retest LoA were -0·056 to 0·056 (mean bias <-0·001 mm). Intra-operator LoA at 1 week were -0·052 to 0·068 mm (mean bias 0·008 mm). Novice operators produce acceptable short-term and 1-week inter- and intra-operator C-IMT measurement variability in healthy, young to middle-aged adults using the Panasonic CardioHealth Station.

          Related collections

          Author and article information

          Journal
          Clin Physiol Funct Imaging
          Clinical physiology and functional imaging
          Wiley
          1475-097X
          1475-0961
          Jan 2016
          : 36
          : 1
          Affiliations
          [1 ] Department of Sport, Health & Exercise Science, University of Hull, Kingston-upon-Hull, UK.
          [2 ] Julius Center for Health Sciences and Primary Care, University Medical Center, Utrecht, The Netherlands.
          Article
          10.1111/cpf.12189
          25216303
          4574579f-ada8-4870-ade9-4e56f372da4e
          History

          reliability,reproducibility,ultrasound,C-IMT,carotid intima-media thickness

          Comments

          Comment on this article

          scite_

          Similar content18

          Cited by3