      Regularization Techniques for ECG Imaging during Atrial Fibrillation: A Computational Study

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The inverse problem of electrocardiography is usually analyzed during stationary rhythms. However, the performance of the regularization methods under fibrillatory conditions has not been fully studied. In this work, we assessed different regularization techniques during atrial fibrillation (AF) for estimating four target parameters, namely, epicardial potentials, dominant frequency (DF), phase maps, and singularity point (SP) location. We use a realistic mathematical model of atria and torso anatomy with three different electrical activity patterns (i.e., sinus rhythm, simple AF, and complex AF). Body surface potentials (BSP) were simulated using Boundary Element Method and corrupted with white Gaussian noise of different powers. Noisy BSPs were used to obtain the epicardial potentials on the atrial surface, using 14 different regularization techniques. DF, phase maps, and SP location were computed from estimated epicardial potentials. Inverse solutions were evaluated using a set of performance metrics adapted to each clinical target. For the case of SP location, an assessment methodology based on the spatial mass function of the SP location, and four spatial error metrics was proposed. The role of the regularization parameter for Tikhonov-based methods, and the effect of noise level and imperfections in the knowledge of the transfer matrix were also addressed. Results showed that the Bayes maximum-a-posteriori method clearly outperforms the rest of the techniques but requires a priori information about the epicardial potentials. Among the purely non-invasive techniques, Tikhonov-based methods performed as well as more complex techniques in realistic fibrillatory conditions, with a slight gain between 0.02 and 0.2 in terms of the correlation coefficient. Also, the use of a constant regularization parameter may be advisable since the performance was similar to that obtained with a variable parameter (indeed there was no difference for the zero-order Tikhonov method in complex fibrillatory conditions). Regarding the different targets, DF and SP location estimation were more robust with respect to pattern complexity and noise, and most algorithms provided a reasonable estimation of these parameters, even when the epicardial potentials estimation was inaccurate. Finally, the proposed evaluation procedure and metrics represent a suitable framework for techniques benchmarking and provide useful insights for the clinical practice.

          Related collections

          Most cited references22

          • Record: found
          • Abstract: not found
          • Article: not found

          ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: full text: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 guidelines for the management of patients with atrial fibrillation) developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Noninvasive electrocardiographic imaging of arrhythmogenic substrates in humans.

            Yoram Rudy (2013)
            Cardiac excitation is determined by interactions between the source of electric activation (membrane depolarization) and the load that cardiac tissue presents. This relationship is altered in pathology by remodeling processes that often create a substrate favoring the development of cardiac arrhythmias. Most studies of arrhythmia mechanisms and arrhythmogenic substrates have been conducted in animal models, which may differ in important ways from the human pathologies they are designed to represent. Electrocardiographic imaging is a noninvasive method for mapping the electric activity of the heart in humans in real-world conditions. This review summarizes results from electrocardiographic imaging studies of arrhythmogenic substrates associated with human clinical arrhythmias. Examples include heart failure, myocardial infarction scar, atrial fibrillation, and abnormal ventricular repolarization.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Direct or coincidental elimination of stable rotors or focal sources may explain successful atrial fibrillation ablation: on-treatment analysis of the CONFIRM trial (Conventional ablation for AF with or without focal impulse and rotor modulation).

              This study sought to determine whether ablation of recently described stable atrial fibrillation (AF) sources, either directly by Focal Impulse and Rotor Modulation (FIRM) or coincidentally when anatomic ablation passes through AF sources, may explain long-term freedom from AF. It is unclear why conventional anatomic AF ablation can be effective in some patients yet ineffective in others with similar profiles. The CONFIRM (Conventional Ablation for AF With or Without Focal Impulse and Rotor Modulation) trial prospectively revealed stable AF rotors or focal sources in 98 of 101 subjects with AF at 107 consecutive ablation cases. In 1:2 fashion, subjects received targeted source ablation (FIRM) followed by conventional ablation, or conventional ablation alone. We determined whether ablation lesions on electroanatomic maps passed through AF sources on FIRM maps. Subjects who completed follow-up (n = 94; 71.2% with persistent AF) showed 2.3 ± 1.1 concurrent AF rotors or focal sources that lay near pulmonary veins (22.8%), left atrial roof (16.0%), and elsewhere in the left (28.2%) and right (33.0%) atria. AF sources were ablated directly in 100% of FIRM cases and coincidentally (e.g., left atrial roof) in 45% of conventional cases (p < 0.05). During a median (interquartile range) of 273 days (138 to 636 days) after one procedure, AF was absent in 80.3% of patients if sources were ablated but in only 18.2% of patients if sources were missed (p < 0.001). Freedom from AF was highest if all sources were ablated, intermediate if some sources were ablated, and lowest if no sources were ablated (p < 0.001). Elimination of stable AF rotors and focal sources may explain freedom from AF after diverse approaches to ablation. Patient-specific AF source distributions are consistent with the reported success of specific anatomic lesion sets and of widespread ablation. These results support targeting AF sources to reduce unnecessary ablation, and motivate studies on FIRM-only ablation. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Physiol
                Front Physiol
                Front. Physiol.
                Frontiers in Physiology
                Frontiers Media S.A.
                1664-042X
                14 October 2016
                2016
                : 7
                : 466
                Affiliations
                [1] 1Department of Telecommunication Engineering, Universidad Rey Juan Carlos Fuenlabrada, Spain
                [2] 2ITACA, Universitat Politécnica de Valencia Valencia, Spain
                [3] 3Instituto de Investigación Sanitaria Gregorio Marañón, Hospital General Univesitario Gregorio Marañón, Universidad Complutense-Facultad de Medicina Madrid, Spain
                Author notes

                Edited by: Olivier Bernus, University of Bordeaux 1, France

                Reviewed by: David R. Van Wagoner, Cleveland Clinic Lerner College of Medicine, USA; Olaf Doessel, Karlsruhe Institute of Technology, Germany; Laura Bear, Ihu-Liryc, France

                *Correspondence: Carlos Figuera carlos.figuera@ 123456urjc.es

                This article was submitted to Cardiac Electrophysiology, a section of the journal Frontiers in Physiology

                Article
                10.3389/fphys.2016.00466
                5064166
                457f5ce3-9c69-4fdd-afd8-68455819523f
                Copyright © 2016 Figuera, Suárez-Gutiérrez, Hernández-Romero, Rodrigo, Liberos, Atienza, Guillem, Barquero-Pérez, Climent and Alonso-Atienza.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 15 July 2016
                : 27 September 2016
                Page count
                Figures: 15, Tables: 0, Equations: 10, References: 52, Pages: 17, Words: 9358
                Funding
                Funded by: Ministerio de Economía y Competitividad 10.13039/501100003329
                Award ID: TEC2013-46067-R
                Categories
                Physiology
                Original Research

                Anatomy & Physiology
                atrial fibrillation,ecg imaging,regularization,dominant frequency,rotor location,inverse problem

                Comments

                Comment on this article