      Characterisation of energy response of Al(2)O(3):C optically stimulated luminescent dosemeters (OSLDs) using cavity theory.

      1 ,
      Radiation protection dosimetry
      Oxford University Press (OUP)

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Aluminium oxide (Al(2)O(3):C) is a common material used in optically stimulated luminescent dosemeters (OSLDs). OSLDs have a known energy dependence, which can impact on the accuracy of dose measurements, especially for lower photon energies, where the dosemeter can overrespond by a factor of 3-4. The purpose of this work was to characterise the response of Al(2)O(3):C using cavity theory and to evaluate the applicability of this approach for polyenergetic photon beams. The cavity theory energy response showed good agreement (within 2 %) with the corresponding measured values. A comparison with measured values reported in the literature for low-energy polyenergetic spectra showed more varied agreement (within 6 % on average). The discrepancy between these results is attributed to differences in the raw photon energy spectra used to calculate the energy response. Analysis of the impact of the photon energy spectra versus the mean photon energy showed improved accuracy if the energy response was determined using the entire photon spectrum rather than the mean photon energy. If not accounted for, the overresponse due to photon energy could introduce substantial inaccuracy in dose measurement using OSLDs, and the results of this study indicate that cavity theory may be used to determine the response with reasonable accuracy.

          Related collections

          Author and article information

          Journal
          Radiat Prot Dosimetry
          Radiation protection dosimetry
          Oxford University Press (OUP)
          1742-3406
          0144-8420
          Jan 2013
          : 153
          : 1
          Affiliations
          [1 ] Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.
          Article
          ncs086
          10.1093/rpd/ncs086
          3528097
          22653437
          45f07f56-af3a-44a1-8e2c-021e301645c8
          History

          Comments

          Comment on this article