      Oximetria de pulso na avaliação do transporte de oxigênio em pacientes críticos Translated title: Oximetría de pulso en la evaluación del transporte de oxígeno en pacientes críticos Translated title: Pulse oximeters in the evaluation of oxygen transportation in critical patients

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Neste estudo a monitorização de 35 pacientes de terapia intensiva, submetidos a ventilação mecânica, permitiu estabelecer o nível de precisão de dois oxímetros de pulso de diferentes fabricantes. O desempenho foi determinado em função de dados comparativos obtidos pela hemo-oximetria, para proceder a análise estatística foi utilizado o teste t. Pacientes críticos são portadores de condições clínicas que podem, eventualmente, limitar o uso desta técnica. No presente trabalho foi demonstrado que a discrepância nos resultados obtidos pode ser atribuída a presença de metemoglobina e possivelmente à anemia associada a hipóxia.

          Translated abstract

          En este estudio el monitoraron 35 pacientes de cuidado intensivo, submetidos a ventilación mecánica, permitiendo establecer el nivel de precisión de 2(dos) oxímetros de pulso de diferentes fabricantes. El desempeño fue determinado en función de datos comparativos obtenidos por la hemo-oximetría. Para proceder al análisis estadístico, fue utilizado el ensayo t. pacientes críticos son portadores de condiciones clínicas que pueden, eventualmente, limitar el uso de esta técnica. En el presente trabajo, fue demostrado que la discrepancia en los resultados obtenidos, puede ser atribuida a la presencia de metemoglobina e posiblemente a la anemia asociada a la hipoxia.

          Translated abstract

          In this clinical investigation 35 patients under mechanical ventilation were studied. It was possible to establish the precision of two pulse oximeters of different brands. The performance of these equipments was evaluated by comparing data with the hemo-oximeter and a statistical analysis employed the student t test. Results showed that bias between oximeters reading and hemo-oximeter was similar for both instruments. Eventually critical patients may present conditions that limit the use of this technique. The study showed that the discrepancy in the results observed may be attributed to the presence of the methemoglobin and possible to anaemia associated to hipoxia.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: found
          • Article: not found

          Nitrobenzene poisoning and spurious pulse oximetry.

          The successful management of nitrobenzene poisoning in a 21-year-old patient is presented. We report our experience of ventilatory care with additional intravenous methylene blue and ascorbic acid therapy. Pulse oximeters available at present are not useful in patients treated with methylene blue and should be used cautiously in the presence of cyanosis of unknown aetiology.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Methemoglobinemia and its effects on pulse oximetry

            L DELWOOD (1991)
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Carboxyhemoglobin and pulse oximetry

                Bookmark

                Author and article information

                Contributors
                Role: ND
                Role: ND
                Journal
                rlae
                Revista Latino-Americana de Enfermagem
                Rev. Latino-Am. Enfermagem
                Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo
                1518-8345
                April 1999
                : 7
                : 2
                : 79-85
                Affiliations
                [1 ] Pontifícia Universidade Católica de Campinas
                [2 ] UNICAMP
                [3 ] Universidade de São Paulo
                [4 ] UNICAMP
                Article
                S0104-11691999000200011
                483cb746-7302-473a-957d-282a183b2ca1

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                Product

                SciELO RevOdonto

                Self URI (journal page): http://www.scielo.br/scielo.php?script=sci_serial&pid=0104-1169&lng=en
                Categories
                NURSING

                oximetría,pulso,pacientes críticos,monitoraron,oxymetry,pulse,critical patients,monitoring,oximetria,monitorização

                Comments

                Comment on this article