      Controlling radiofrequency-induced currents in guidewires using parallel transmit : Controlling RF Current Using Parallel Transmit

      , , , ,
      Magnetic Resonance in Medicine
      Wiley

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Elongated conductors, such as pacemaker leads, neurostimulator leads, and conductive guidewires used for interventional procedures can couple to the MRI radiofrequency (RF) transmit field, potentially causing dangerous tissue heating. The purpose of this study was to demonstrate the feasibility of using parallel transmit to control induced RF currents in elongated conductors, thereby reducing the RF heating hazard.

          Related collections

          Most cited references33

          • Record: found
          • Abstract: not found
          • Book: not found

          Time-Harmonic Electromagnetic Fields

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            B1 mapping by Bloch-Siegert shift.

            A novel method for amplitude of radiofrequency field (B1+) mapping based on the Bloch-Siegert shift is presented. Unlike conventionally applied double-angle or other signal magnitude-based methods, it encodes the B(1) information into signal phase, resulting in important advantages in terms of acquisition speed, accuracy, and robustness. The Bloch-Siegert frequency shift is caused by irradiating with an off-resonance radiofrequency pulse following conventional spin excitation. When applying the off-resonance radiofrequency in the kilohertz range, spin nutation can be neglected and the primarily observed effect is a spin precession frequency shift. This shift is proportional to the square of the magnitude of B1(2). Adding gradient image encoding following the off-resonance pulse allows one to acquire spatially resolved B(1) maps. The frequency shift from the Bloch-Siegert effect gives a phase shift in the image that is proportional to B(1)(2). The phase difference of two acquisitions, with the radiofrequency pulse applied at two frequencies symmetrically around the water resonance, is used to eliminate undesired off-resonance effects due to amplitude of static field inhomogeneity and chemical shift. In vivo Bloch-Siegert B(1) mapping with 25 sec/slice is demonstrated to be quantitatively comparable to a 21-min double-angle map. As such, this method enables robust, high-resolution B(1)(+) mapping in a clinically acceptable time frame. (c) 2010 Wiley-Liss, Inc.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Parallel excitation with an array of transmit coils.

              Y. Zhu (2004)
              Theoretical and experimental results are presented that establish the value of parallel excitation with a transmit coil array in accelerating excitation and managing RF power deposition. While a 2D or 3D excitation pulse can be used to induce a multidimensional transverse magnetization pattern for a variety of applications (e.g., a 2D localized pattern for accelerating spatial encoding during signal acquisition), it often involves the use of prolonged RF and gradient pulses. Given a parallel system that is composed of multiple transmit coils with corresponding RF pulse synthesizers and amplifiers, the results suggest that by exploiting the localization characteristics of the coils, an orchestrated play of shorter RF pulses can achieve desired excitation profiles faster without adding strains to gradients. A closed-form design for accelerated multidimensional excitations is described for the small-tip-angle regime, and its suppression of interfering aliasing lobes from coarse excitation k-space sampling is interpreted based on an analogy to sensitivity encoding (SENSE). With or without acceleration, the results also suggest that by taking advantage of the extra degrees of freedom inherent in a parallel system, parallel excitation provides better management of RF power deposition while facilitating the faithful production of desired excitation profiles. Sample accelerated and specific absorption rate (SAR)-reduced excitation pulses were designed in this study, and evaluated in experiments. Copyright 2004 Wiley-Liss, Inc.
                Bookmark

                Author and article information

                Journal
                Magnetic Resonance in Medicine
                Magn. Reson. Med.
                Wiley
                07403194
                December 2015
                December 17 2015
                : 74
                : 6
                : 1790-1802
                Article
                10.1002/mrm.25543
                4470871
                25521751
                4a6e329b-e568-4cea-8957-96605492c929
                © 2015

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article

                scite_

                Similar content4,057

                Cited by15

                Most referenced authors325