29
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap.

      Journal of Glaucoma
      Aged, Antihypertensive Agents, administration & dosage, Female, Follow-Up Studies, Glaucoma, physiopathology, surgery, Glaucoma Drainage Implants, Humans, Intraocular Pressure, physiology, Male, Prosthesis Implantation, methods, Retrospective Studies, Sclera, Surgical Flaps, Tonometry, Ocular, Trabeculectomy, Treatment Outcome

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To evaluate the Ex-PRESS miniature implant (Model R 50) placed under partial-thickness scleral flap compared with standard trabeculectomy. In this retrospective comparative series of 100 eyes, we compared 50 eyes in 49 patients treated with the Ex-PRESS miniature glaucoma implant under a scleral flap with 50 matched control eyes in 47 patients treated with trabeculectomy. Success was defined as intraocular pressure (IOP) > or =5 mm Hg and < or =21 mm Hg, with or without glaucoma medications, without further glaucoma surgery or removal of implant. Early postoperative hypotony was defined as IOP <5 mm Hg during the first postoperative week. The average follow-up was 10.8 months (range 3.5 to 18) for the Ex-PRESS group and 11.2 months (range 3 to 15) for the trabeculectomy group. Although the mean IOP was significantly higher in the early postoperative period in the Ex-PRESS group compared with the trabeculectomy group, the reduction of IOP was similar in both groups after 3 months. The number of postoperative glaucoma medications in both groups was not significantly different. Kaplan-Meier survival curve analysis showed no significant difference in success between the 2 groups (P=0.594). Early postoperative hypotony and choroidal effusion were significantly more frequent after trabeculectomy compared with Ex-PRESS implant under scleral flap (P<0.001). The Ex-PRESS implant under a scleral flap had similar IOP-lowering efficacy with a lower rate of early hypotony compared with trabeculectomy.

          Related collections

          Author and article information

          Comments

          Comment on this article