24
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Three-Dimensional Imaging of a Central Venous Dialysis Catheter Related Infected Thrombus

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Three-dimensional (3D) echocardiography is becoming widely available and with novel applications. We report an interesting case of a 68-year-old lady with a central venous thrombosis coincident with both a dialysis catheter infection and a recent pacemaker insertion. Two-dimensional transesophageal echocardiography was unable to delineate whether the thrombosis was involved with the pacemaker wire or due to the tunneled catheter infection. The use of 3D echocardiography was able to produce distinct images aiding diagnosis. This circumvented the need for invasive investigations and inappropriate, high-risk removal of the pacing wire. This case highlights the emerging application of 3D echocardiography in routine nephrology practice.

          Related collections

          Most cited references8

          • Record: found
          • Abstract: found
          • Article: not found

          Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography.

          We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE). Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated. Unselected patients (n = 50; 41 men; age, 64 +/- 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line. The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 +/- 53 ml; LV volumes were underestimated by 2DE (mean difference, -54 +/- 33; p < 0.01) but only slightly by RT-3DE (-4 +/- 29; p = 0.31). Similarly, end-systolic volume by MRI (91 +/- 53 ml) was underestimated by 2DE (mean difference, -28 +/- 28; p < 0.01) and by RT-3DE (mean difference, -3 +/- 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 +/- 50 g) was overestimated by M-mode (mean difference, 68 +/- 86 g; p < 0.01) and 2DE (16 +/- 57; p = 0.04) but not RT-3DE (0 +/- 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass. Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Fast measurement of left ventricular mass with real-time three-dimensional echocardiography: comparison with magnetic resonance imaging.

            Left ventricular (LV) mass is an important predictor of morbidity and mortality, especially in patients with systemic hypertension. However, the accuracy of 2D echocardiographic LV mass measurements is limited because acquiring anatomically correct apical views is often difficult. We tested the hypothesis that LV mass could be measured more accurately from real-time 3D (RT3D) data sets, which allow offline selection of nonforeshortened apical views, by comparing 2D and RT3D measurements against cardiac MR (CMR) measurements. Echocardiographic imaging was performed (Philips 7500) in 21 patients referred for CMR imaging (1.5 T, GE). Apical 2- and 4-chamber views and RT3D data sets were acquired and analyzed by 2 independent observers. The RT3D data sets were used to select nonforeshortened apical 2- and 4-chamber views (3DQ-QLAB, Philips). In both 2D and RT3D images, LV long axis was measured; endocardial and epicardial boundaries were traced, and mass was calculated by use of the biplane method of disks. CMR LV mass values were obtained through standard techniques (MASS Analysis, GE). The RT3D data resulted in significantly larger LV long-axis dimensions and measurements of LV mass that correlated with CMR better (r=0.90) than 2D (r=0.79). The 2D technique underestimated LV mass (bias, 39%), whereas RT3D measurements showed only minimal bias (3%). The 95% limits of agreement were significantly wider for 2D (52%) than RT3D (28%). Additionally, the RT3D technique reduced the interobserver variability (37% to 7%) and intraobserver variability (19% to 8%). RT3D imaging provides the basis for accurate and reliable measurement of LV mass.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Thrombotic and infectious complications of central venous catheters in patients with hematological malignancies.

              Central venous catheters (CVCs) have considerably improved the management of patients with hematological malignancies, by facilitating chemotherapy, supportive therapy and blood sampling. Complications of insertion of CVCs include mechanical (arterial puncture, pneumothorax), thrombotic and infectious complications. CVC-related thrombosis and infections are frequently occurring complications and may cause significant morbidity in patients with hematological malignancies. CVC-related thrombosis and infections are related and can therefore not be seen as separate entities. The incidence of symptomatic CVC-related thrombosis had been reported to vary between 1.2 and 13.0% of patients with hematological malignancy. The incidence of CVC-related bloodstream infections varies between 0.0 and 20.8%. There is need for a specific approach regarding diagnosis and treatment of CVC-related thrombosis and infection with specific attention to the preservation of the catheter. Since data on CVC-related infections and thrombosis in hematological patients have been obtained mainly from retrospective studies of small sample size, prospective, randomized studies of prophylactic measures concerning CVC-related thrombosis and infection are warranted.
                Bookmark

                Author and article information

                Journal
                Case Rep Nephrol
                Case Rep Nephrol
                CRIN
                Case Reports in Nephrology
                Hindawi Publishing Corporation
                2090-6641
                2090-665X
                2015
                24 November 2015
                : 2015
                : 724132
                Affiliations
                1Vascular Research Group, Institute of Population Health, The University of Manchester, Manchester Academic Health Sciences Centre, Manchester M13 9PL, UK
                2Department of Renal Medicine, Salford Royal NHS Foundation Trust, Stott Lane, Salford M6 8HD, UK
                3Department of Cardiology, Salford Royal Hospital, Salford Royal NHS Foundation Trust, Stott Lane, Salford M6 8HD, UK
                Author notes

                Academic Editor: Kostas C. Siamopoulos

                Article
                10.1155/2015/724132
                4672108
                4c196fc7-9cf3-4a06-8fbe-9e5a4005663f
                Copyright © 2015 Diana Yuan Yng Chiu et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 27 August 2015
                : 22 October 2015
                Categories
                Case Report

                Comments

                Comment on this article