      Two novel zeolitic imidazolate frameworks (ZIFs) as sorbents for solid-phase extraction (SPE) of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In this work, two novel zeolitic imidazolate framework (ZIF) materials, ZIF-7 and ZIF-11, were firstly introduced as solid-phase extraction (SPE) sorbents for PAHs efficient extraction and highly sensitive analysis in environmental water samples with high performance liquid chromatography (HPLC) coupled with fluorescence detection. ZIF-7 and ZIF-11 were successfully synthesized and characterized with SEM, FTIR, XRD and water contact angels, exhibiting unique and excellent stability, spatial structure and chemical composition, promising for environmental PAHs efficient enrichment through hydrophobic, π-π and π-complexation interactions. The topology effect on PAHs extraction was compared between ZIF-7 and ZIF-11, considering they have the same composition in metal ion (Zn(2+)) and organic linker, but differing spatial structures: ZIF-7 has a cubic structure, while ZIF-11 is a rhombic dodecahedron. At last, ZIF-11 with markedly better extraction efficiencies was selected for subsequent analysis. Under optimum extraction conditions such as sample volume, extraction time, desorption conditions, volume of organic modifier and salt concentration, a robust and highly efficient method based on ZIF-11 as a novel SPE sorbent has been successfully developed for environmental PAHs analysis. Satisfactory precision and accuracy ranging from 1-2.4 × 10(3) ng L(-1) as well as ultrasensitive detection limits of 0.08-1.6 ng L(-1) have been successfully achieved. Moreover, ZIF-11 extraction also exhibited high recoveries of 82.4-112.7% with relative standard deviations (RSDs) being less than 9% for PAHs in the environmental water samples. Therefore, our novel, convenient and efficient extraction method based on ZIF-11 as a sorbent is promising for applications in future trace-level environmental PAHs analyses.

          Related collections

          Author and article information

          Journal
          Analyst
          The Analyst
          Royal Society of Chemistry (RSC)
          1364-5528
          0003-2654
          Nov 21 2014
          : 139
          : 22
          Affiliations
          [1 ] State Key Laboratory of Chemo/Biosensing & Chemometrics, College of Chemistry & Chemical Engineering, Hunan University, Changsha 410082, China. szyao@hnu.edu.cn shengquanliu7068@163.com.
          Article
          10.1039/c4an01410c
          25209546