      A head-mounted operating binocular for augmented reality visualization in medicine--design and initial evaluation.

      IEEE transactions on medical imaging
      Calibration, Computer Graphics, Depth Perception, Equipment Design, Equipment Failure Analysis, Imaging, Three-Dimensional, instrumentation, methods, Microscopy, Video, Microsurgery, Reproducibility of Results, Sensitivity and Specificity, Subtraction Technique, Surgical Equipment, User-Computer Interface, Video Recording

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer-generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the realworld scene and the computer-generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost-effective head-mounted operating binocular, for AR. In this paper, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscope's computer displays to a real-world scene. In a series of 16 calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24 +/- 0.38 pixels or 0.12 +/- 0.05 mm for a 640 x 480 display. Maximum error accounted for 3.33 +/- 1.04 pixels or 0.33 +/- 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: not found
          • Article: not found

          A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses

          R Tsai (1987)
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Predicting error in rigid-body point-based registration.

            Guidance systems designed for neurosurgery, hip surgery, and spine surgery, and for approaches to other anatomy that is relatively rigid can use rigid-body transformations to accomplish image registration. These systems often rely on point-based registration to determine the transformation, and many such systems use attached fiducial markers to establish accurate fiducial points for the registration, the points being established by some fiducial localization process. Accuracy is important to these systems, as is knowledge of the level of that accuracy. An advantage of marker-based systems, particularly those in which the markers are bone-implanted, is that registration error depends only on the fiducial localization error (FLE) and is thus to a large extent independent of the particular object being registered. Thus, it should be possible to predict the clinical accuracy of marker-based systems on the basis of experimental measurements made with phantoms or previous patients. This paper presents two new expressions for estimating registration accuracy of such systems and points out a danger in using a traditional measure of registration accuracy. The new expressions represent fundamental theoretical results with regard to the relationship between localization error and registration error in rigid-body, point-based registration. Rigid-body, point-based registration is achieved by finding the rigid transformation that minimizes "fiducial registration error" (FRE), which is the root mean square distance between homologous fiducials after registration. Closed form solutions have been known since 1966. The expected value (FRE2) depends on the number N of fiducials and expected squared value of FLE, (FLE-2, but in 1979 it was shown that (FRE2) is approximately independent of the fiducial configuration C. The importance of this surprising result seems not yet to have been appreciated by the registration community: Poor registrations caused by poor fiducial configurations may appear to be good due to a small FRE value. A more critical and direct measure of registration error is the "target registration error" (TRE), which is the distance between homologous points other than the centroids of fiducials. Efforts to characterize its behavior have been made since 1989. Published numerical simulations have shown that (TRE2) is roughly proportional to (FLE2)/N and, unlike (FRE2), does depend in some way on C. Thus, FRE, which is often used as feedback to the surgeon using a point-based guidance system, is in fact an unreliable indicator of registration-accuracy. In this work we derive approximate expressions for (TRE2), and for the expected squared alignment error of an individual fiducial. We validate both approximations through numerical simulations. The former expression can be used to provide reliable feedback to the surgeon during surgery and to guide the placement of markers before surgery, or at least to warn the surgeon of potentially dangerous fiducial placements; the latter expression leads to a surprising conclusion: Expected registration accuracy (TRE) is worst near the fiducials that are most closely aligned! This revelation should be of particular concern to surgeons who may at present be relying on fiducial alignment as an indicator of the accuracy of their point-based guidance systems.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Design and evaluation of a system for microscope-assisted guided interventions (MAGI).

              The problem of providing surgical navigation using image overlays on the operative scene can be split into four main tasks--calibration of the optical system; registration of preoperative images to the patient; system and patient tracking, and display using a suitable visualization scheme. To achieve a convincing result in the magnified microscope view a very high alignment accuracy is required. We have simulated an entire image overlay system to establish the most significant sources of error and improved each of the stages involved. The microscope calibration process has been automated. We have introduced bone-implanted markers for registration and incorporated a locking acrylic dental stent (LADS) for patient tracking. The LADS can also provide a less-invasive registration device with mean target error of 0.7 mm in volunteer experiments. These improvements have significantly increased the alignment accuracy of our overlays. Phantom accuracy is 0.3-0.5 mm and clinical overlay errors were 0.5-1.0 mm on the bone fiducials and 0.5-4 mm on target structures. We have improved the graphical representation of the stereo overlays. The resulting system provides three-dimensional surgical navigation for microscope-assisted guided interventions (MAGI).