37
views
0
recommends
+1 Recommend
1 collections
    0
    shares

      Call for Papers: Green Renal Replacement Therapy: Caring for the Environment

      Submit here before July 31, 2024

      About Blood Purification: 3.0 Impact Factor I 5.6 CiteScore I 0.83 Scimago Journal & Country Rank (SJR)

      • Record: found
      • Abstract: found
      • Article: found

      Analysis of Urea Distribution Volume in Hemodialysis

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          According to the urea kinetic model it is considered that the urea distribution volume (V) is that of body water, and that it is distributed in only one compartment. Since the V value is difficult to measure, it is normal to use 58% of body weight, in spite of the fact that it may range from 35 to 75%. In this study, we have calculated the value of V by using an accurate method based on the total elimination of urea from the dialysate. We have studied the V, and also whether the different dialysis characteristics modify it. Thirty-five patients were included in this study, 19 men and 16 women, under a chronic hemodialysis programme. The dialysate was collected in a graduated tank, and the concentration of urea in plasma and in dialysate were determined every hour. Every patient received six dialysis sessions, changing the blood flow (250 or 350 ml/min), the ultrafiltration (0.5 or 1.51/h), membrane (cuprophane or polyacrylonitrile) and/or buffer (bicarbonate or acetate). At the end of the hemodialysis session, the V value ranged from 43 to 72% of body weight; nevertheless, this value was practically constant in every patient. The V value gradually increased throughout the dialysis session, 42.1 ± 6.9% of body weight in the first hour, 50.7 ± 7.5% in the second hour and 55.7 ± 7.9% at the end of the dialysis session. The change of blood flow, ultrafiltration, membrane or buffer did not alter the results. The V value was significantly higher in men in comparison with women, 60.0 ± 6.6% vs. 50.5 ± 5.9% of body weight (p < 0.001).

          Related collections

          Author and article information

          Journal
          NEF
          Nephron
          10.1159/issn.1660-8151
          Nephron
          S. Karger AG
          1660-8151
          2235-3186
          1994
          1994
          16 December 2008
          : 66
          : 3
          : 312-316
          Affiliations
          aDepartments of Nephrology and bBiochemistry, Hospital ‘Lluis Alcanyis’ Xàtiva, Spain
          Article
          187829 Nephron 1994;66:312–316
          10.1159/000187829
          8190184
          4d593a34-ce26-4bde-a7d6-cf31cd9fd381
          © 1994 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          : 26 April 1993
          Page count
          Pages: 5
          Categories
          Original Paper

          Cardiovascular Medicine,Nephrology
          Urea distribution volume,Adequate dialysis,Urea kinetic model

          Comments

          Comment on this article