39
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Comparison of nasopharyngeal aspirate and nasopharyngeal swab specimens for respiratory syncytial virus diagnosis by cell culture, indirect immunofluorescence assay, and enzyme-linked immunosorbent assay.

      Journal of Clinical Microbiology
      Animals, Autoradiography, Bronchiolitis, Viral, diagnosis, Cell Line, Cells, Cultured, Cytopathogenic Effect, Viral, DNA, analysis, Enzyme-Linked Immunosorbent Assay, Fluorescent Antibody Technique, Humans, Infant, Nasopharynx, microbiology, Nucleic Acid Hybridization, Pneumonia, Viral, Predictive Value of Tests, Respiratory Syncytial Viruses, isolation & purification, Respirovirus Infections, Specimen Handling

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Paired nasopharyngeal aspirate (NPA) and nasopharyngeal swab (NPS) specimens obtained from each of 32 hospitalized infants with X-ray-confirmed pneumonia (91%) or bronchiolitis were tested for respiratory syncytial virus (RSV) infection by virus culture, the indirect immunofluorescent-antibody (IFA) technique, enzyme-linked immunosorbent assay (ELISA; Ortho Diagnostic Systems, Inc.), and spot hybridization with a human genomic probe to quantitate cellular DNA. RSV was isolated in cell cultures from 72% (23 of 32) of patients by using NPA specimens compared with 47% (15 of 32) by using NPS specimens. With tissue culture positivity as the reference test, the sensitivities of the ELISA on NPA and NPS specimens were found to be 69% (16 of 23) and 61% (14 of 23), respectively, with a specificity and a positive predictive value from both sites of 100%. The sensitivities of the IFA technique compared with the cell culture on NPA and NPS specimens were 61% (14 of 23) and 52% (12 of 23) with specificities of 89 and 78% and positive predictive values of 96 and 92%, respectively. Despite the recovery of significantly more cells (as shown by detection of more cellular DNA by using NPA specimens), virus was detected by the IFA technique or ELISA at similar frequencies in paired specimens. However, virus was recovered more often from NPA than NPS specimens by cell culture, and ELISA optical density readings and the number of RSV-positive fluorescing cells were greater for NPA specimens. NPA specimen collection was less traumatic for the patient, was an easier procedure for the physician to perform, and provided a superior laboratory specimen for RSV diagnosis than the NPS technique.

          Related collections

          Author and article information

          Comments

          Comment on this article